5.4 Changing Hardware Settings
84
Display Color
Select the grid (graticule) type for the waveform screen. Sets the screen color.
Beep sound
Sets whether to beep when a key is pressed.
LCD Backlight
The LCD backlight can be set to turn off after a set period of time.
Pressing a key will cause the screen to be displayed again.
Clock
Sets the time and date, which are used to record and manage data.
Be sure to set the time and date before starting recording (seconds cannot be set).
Valid setting range: 00:00 on January 1, 2010 to 23:59 on December 31, 2079.
External output
Set when using the external control terminal to connect the PQ3198 to an external device.
Setting Contents:(
∗
: Default setting)
Color 1
∗
Blue-gray
Color 2
Blue
Color 3
Black
Color 4
Gray
Color 5
White (Convenient when printing screenshots )
Setting Contents:(
∗
: Default setting)
ON
∗
Beeps are enabled.
OFF
Beeps are disabled.
Setting Contents:(
∗
: Default setting)
AUTO
Automatically turns the backlight off once 2 minutes
have elapsed since the last key press.
ON
∗
Leaves the screen backlight on at all times.
Setting Contents:(
∗
: Default setting)
OFF
Disables external output.
Short pulse
∗
A short pulse (approx. 10 ms) is output on recording start, stop, and during event IN.
Long pulse
A long pulse (approx. 2.5 s) is output only during event IN.
Set this function to be combined with the 2300 Remote Measurement System or a
sequencer.
Low period is retained for approx. 2.5 s during event IN. If another event IN occurs during the
Low period, the Low period for is retained for another approx. 2.5 s.
Δ
V10 alarm
This setting can be selected only when the
[Flicker]
setting is
[
Δ
V10]
. Output will be set to
low when the set
Δ
V10 threshold is exceeded. If selecting this setting, set the
Δ
V10 thresh-
old. (0.00 V to 9.99 V)
HIOKI PQ3198A961-03
Содержание PQ3198
Страница 2: ...HIOKI PQ3198A961 03...
Страница 6: ...Contents iv HIOKI PQ3198A961 03...
Страница 20: ...Usage Notes 14 HIOKI PQ3198A961 03...
Страница 44: ...2 3 Display Items and Screen Types 38 HIOKI PQ3198A961 03...
Страница 58: ...3 8 Turning the Power On and Off Setting the Default Language 52 HIOKI PQ3198A961 03...
Страница 102: ...5 8 Factory Settings 96 HIOKI PQ3198A961 03...
Страница 116: ...6 4 Displaying Harmonics 110 Holding the display Hold Measured values and waveforms will be held HIOKI PQ3198A961 03...
Страница 198: ...12 4 Downloading Recorded Data to Computer 192 HIOKI PQ3198A961 03...
Страница 264: ...14 4 Disposing of the Instrument 258 HIOKI PQ3198A961 03...
Страница 296: ...A32 HIOKI PQ3198A961 03...
Страница 299: ...Index Index 3 Index Wiring 73 Z Zero adjustment 53 Zero phase A28 HIOKI PQ3198A961 03...
Страница 300: ...Index Index 4 HIOKI PQ3198A961 03...
Страница 301: ...HIOKI PQ3198A961 03...
Страница 302: ...HIOKI PQ3198A961 03...
Страница 303: ...HIOKI PQ3198A961 03...
Страница 304: ...www hioki com HIOKI PQ3198A961 03...