Appendix
Appendix12 Initial Settings Table
A19
LCR mode
DC resistance
measurement
Temperature
correction
ON/OFF
OFF
No
Yes
No
No
Yes
Reference
temperature
20.0°C
No
Yes
No
No
Yes
Temperature
coefficient
3930 ppm
No
Yes
No
No
Yes
DC delay
0.0000 s
No
Yes
No
No
Yes
ADJ delay
0.0030 s
No
Yes
No
No
Yes
Line frequency
60 Hz
No
Yes
No
No
Yes
Measurement range
Mode
AUTO
No
Yes
No
No
Yes
AUTO range limit
function
100 m
/
100 M
No
Yes
No
No
Yes
Range
100
No
Yes
No
No
Yes
Judgment synchroni-
zation setting
OFF
No
Yes
No
No
Yes
LOW Z
OFF
No
Yes
No
No
Yes
Measurement speed
MED
No
Yes
No
No
Yes
Number of times for average
1
No
Yes
No
No
Yes
DC range
synchronization
function
*3
Measurement speed
MED
No
Yes
No
No
Yes
Number of times for average
1
No
Yes
No
No
Yes
Application
settings
(for all modes)
Judgment mode
OFF
No
Yes
No
Yes
Yes
Memory
OFF/IN/ON
OFF
No
Yes
Yes
Yes
Yes
Number of memory
items
1000
No
Yes
Yes
Yes
Yes
Range synchronization function
OFF
No
Yes
No
Yes
Yes
Waveform averaging
function
ON/OFF
OFF
No
Yes
Yes
Yes
Yes
No. of waveform aver-
ages for each frequen-
cy band
No. of MED
waveform averages
No
Yes
Yes
Yes
Yes
Judgment result
Delay between judg-
ment results and EOM
0.0000 s
No
No
No
No
Yes
Reset
ON
No
No
No
No
Yes
IO trigger
ENABLE
ON
No
No
No
No
Yes
Edge
DOWN
No
No
No
No
Yes
IO EOM
Mode
HOLD
No
No
No
No
Yes
EOM output time
0.0050 s
No
No
No
No
Yes
HIGH-Z Reject
ON/OFF
OFF
No
Yes
Yes
Yes
Yes
Judgment reference
value
1000%
No
Yes
Yes
Yes
Yes
Contact check
Timing
OFF
No
Yes
Yes
Yes
Yes
Threshold
2
No
Yes
Yes
Yes
Yes
Display digits
6/6/6/6
No
Yes
No
Yes
Yes
Backlight
ON/OFF
ON
No
No
No
No
Yes
Beep sound
Judgment result
NG
No
Yes
Yes
Yes
Yes
Key
ON
No
No
No
No
Yes
Beep tone
C
No
No
No
No
Yes
Key-lock
ON/OFF
OFF
No
No
No
No
Yes
Passcode
3533
No
No
No
No
Yes
LCR mode
comparator
Mode
ABS/ABS
No
Yes
No
No
Yes
Absolute value mode
Upper limit value
OFF/OFF
No
Yes
No
No
Yes
Lower limit value
OFF/OFF
No
Yes
No
No
Yes
Percent mode
Deviation percent-
age mode
Reference value
1.0000 k/ 10.0000
No
Yes
No
No
Yes
Upper limit value
OFF/OFF
No
Yes
No
No
Yes
Lower limit value
OFF/OFF
No
Yes
No
No
Yes
Yes: Available/ No: Unavailable/
: The same as the initial settings
Setting Items
Initial setting
instru-
ment
RESET
operati
on full
reset
*RST
:PRESet
Return to
initial
settings
when
power is
turned
on
Panel save/ Load
*1
File
save/
Load
LCR
mode
ANALY
ZER
mode
*2
TRAN
SFOR
MER
mode
Содержание IM3533
Страница 2: ......
Страница 8: ...Contents vi...
Страница 52: ...3 3 When TRANSFORMER Mode 44...
Страница 156: ...4 5 Setting Application Settings 148...
Страница 200: ...5 3 Application Settings 192...
Страница 216: ...6 4 Setting Application Settings 208...
Страница 270: ...9 4 Deleting a Panel 262...
Страница 316: ...11 7 File and Folder Operations 308...
Страница 338: ...12 6 Measurement Using a Computer 330...
Страница 396: ...Appendix 13 Device Compliance Statement A26...
Страница 399: ......
Страница 400: ......