Verifying Package Contents
2
Options
For more information, contact the store (distributor) from which you purchased the instrument or your nearest
HIOKI sales office.
Measurable range: DC to 200 kHz
Maximum voltage:
±
42 Vpeak (AC+DC)
Maximum current:
±
1 Apeak (AC+DC)
Measurement terminal hole diameter: 0.3 mm to 5 mm
L2000 4-terminal Probe
Alligator-clip-type measure-
ment probes. These general-
purpose dual-electrode clips fit
a wide range of conductor
thicknesses.
Measurable range: DC to 5 MHz
Maximum voltage: ±42 Vpeak (AC+DC)
Maximum current: ±1 Apeak (AC+DC)
Measurement terminal hole diameter: 0.3 mm to 5 mm
9140-10 4-terminal Probe
Measurable range: DC to 5 MHz
Maximum voltage:
±
DC30 V
Electrode tip spacing: 0.3 mm to approx. 6 mm
Measurable range: DC to 1 MHz
Maximum voltage: DC
±
40 V (42 Vpeak (Measurement bias voltage))
Maximum current: 1 Apeak (Measurement bias current)
Measurement terminal hole diameter: 0.3 mm to 2 mm
Rubber-sheathed alligator
clip type
9500-10 4-terminal Probe
Pincher type
9143-10 Pincher Probe
9261-10 Test Fixture
Measurable range: 42 Hz to 5 MHz
Maximum applied voltage: DC±40 V
Test sample dimensions: Lead diameter of 0.3 mm to 2 mm
Lead pitch of 5 mm or more
This fixture is for measuring
lead components. (less than
10 m
residual resistance
after zero adjustment)
9262 Test Fixture
easurable range: DC to 5 MHz
Maximum applied voltage: DC
±
40 V
Measurement terminal hole diameter: 0.3 mm to 1.5 mm
9263 SMD Test Fixture
This fixture is for measuring chip
components. (less than 10 m
residual resistance after zero ad-
justment)
Measurable range: DC to 120 MHz
Maximum applied voltage: DC±40 V
Test sample width of 3.5±0.5 mm or less
Measurable range: DC to 5 MHz
Maximum applied voltage: DC±40 V
Test sample dimensions: Test sample width of 1 to 10 mm
9677 SMD Test Fixture
9268-10 DC Bias Voltage Unit
Measurable range: 40 Hz to 2 MHz
Maximum applied current: DC2 A
Measurable range: 40 Hz to 5 MHz
Maximum applied voltage: DC
±
40 V
9269-10 DC Bias Current Unit
This fixture is for the lower
electrode.
Measurable range: DC to 120 MHz
Maximum applied voltage: DC±40 V
Test sample dimensions: Test sample width of 1 to 4 mm
Test sample height of 1.5 mm or less
Platinum resistance bulb (Pt100), waterproof design
(EN60529:1991,IP67)
Measurable range: -10.0°C to 99.9°C
Tip diameter:
2.3 mm
Cord length: 1 m
9699 SMD Test Fixture
9478 Temperature Probe
Z3000
GP-IB Interface
Z3001
RS-232C Interface
Z3002
LAN Interface
Содержание IM3533
Страница 2: ......
Страница 8: ...Contents vi...
Страница 52: ...3 3 When TRANSFORMER Mode 44...
Страница 156: ...4 5 Setting Application Settings 148...
Страница 200: ...5 3 Application Settings 192...
Страница 216: ...6 4 Setting Application Settings 208...
Страница 270: ...9 4 Deleting a Panel 262...
Страница 316: ...11 7 File and Folder Operations 308...
Страница 338: ...12 6 Measurement Using a Computer 330...
Страница 396: ...Appendix 13 Device Compliance Statement A26...
Страница 399: ......
Страница 400: ......