5. To apply probe, clean mounting surface with isopropyl alcohol and dry thoroughly.
6. Remove protective backing from double-faced adhesive tape on probe, and press onto
surface.
7. Install supplied cable:
• Route end of cable that has two (2) stripped wires and a quick-connect terminal to the
inside of ATevo enclosure.
• Leave 30in / 762mm of cable inside enclosure. Run cable through a conduit that does not
contain power wiring.
• Route other end of cable to probe at the battery, and coil up excess cable.
• Make sure all wiring conforms to NEC, local, and site requirements
8. Attach interconnection cable to ATevo Power Board (A2-TB8) and EARTH terminal as shown
below:
Do NOT mount probe on: unpainted wood, bare galvanized metal, or plastic
surfaces. Consult battery manufacturer for mounting restrictions and adhesive
compatibilities.
!
HindlePower Inc
ATevo Operations–Single Phase Input–Group II (30-100 Adc Output) - 1_en
Copyright HindlePower Inc. 2021
Page 114 of 171