D4
Yellow/Green SENSOR
Door Contact
D5
Yellow/Gray
BTN
Exit Door
Wiring
4.2 Wire Normal Device
You can connect the terminal with normal peripherals.
The wiring diagram without secure door control unit is as follows.
Figure 4-2 Device Wiring
Note
●
You should set the face recognition terminal's Wiegand direction to "Input" to connect to a
Wiegand card reader. If connects to an access controller, you should set the Wiegand direction to
"Output" to transmit authentication information to the access controller.
●
For details about Wiegand direction settings, see Setting Wiegand Parameters in Communication
Settings.
●
The power supply for the device should be 12 VDC/2 A. The suggested external power supply for
door lock is 12 V, 1 A. The suggested external power supply for the Wiegand card reader is 12 V,
1A.