Figure 8-16 Temperature Measurement Settings
2. Enable Temperature Measurement.
3. Configure the temperature measurement parameters.
Enable Temperature Detection
When enabling the function, the device will authenticate the permissions and at the same
time take the temperature. When disabling the device, the device will authenticate the
permissions only.
Over-Temperature Alarm Threshold (Max./Min.)
Edit the threshold according to actual situation. If the detected temperature is higher or
lower than the configured parameters, an alarm will be triggered. By default, the value is
37.3°.
Temperature Compensation
If the measured temperature is higher/lower than the actual object's temperature, you can
set the compensation temperature here. Available range: -99 °C to 99 °C.
Door Not Open When Temperature is Abnormal
When enabling the function, the door will not open when the detected temperature is higher
or lower than the configured temperature threshold. By default, the function is enabled.
Temperature Measurement Only
DS-K1TA70 Series Face Recognition Terminal User Manual
102
Содержание DS-K1TA70MI-T
Страница 1: ...DS K1TA70 Series Face Recognition Terminal User Manual...
Страница 20: ...Figure 2 1 Face Recognition Terminal Diagram DS K1TA70 Series Face Recognition Terminal User Manual 4...
Страница 37: ...Figure 4 8 Device Wiring Figure 4 9 Wiring Diagram DS K1TA70 Series Face Recognition Terminal User Manual 21...
Страница 59: ...Figure 7 7 Add Face Picture 6 Look at the camera DS K1TA70 Series Face Recognition Terminal User Manual 43...
Страница 225: ...Appendix C Dimension DS K1TA70 Series Face Recognition Terminal User Manual 209...
Страница 227: ...UD22684B D...