Malfunction
Cause
Rectification
Motor always switching
off.
Cutter blocked.
Remove blockage.
Mechanical damage in
the shearing handpiece
or flexi-shaft.
For the purposes of fault
finding first of all uncouple
the shearing handpiece
and restart the plant. If the
fault persists, uncouple
the rigid drive downtube
or flexible drive from the
shearing plant. Rectify any
damage.
If the fault still persists,
then have the shearing
plant repaired.
Reverberation sensor’s
magnet faulty.
Have the insulation flange,
inc. magnet, replaced.
Faulty reverberation
sensor.
Have the reverberation
sensor replaced.
Power supply too weak.
Check the power supply.
Motor system does not
switch off by lock up.
Control unit faulty.
Have control unit replaced.
Shearing unit is noisy or
vibrates.
Faulty motor bearing.
Have the motor replaced.
Motor gets hot.
Faulty motor bearing.
Have the motor replaced.
Ventilation screen dirty.
Clean ventilation screen.
Malfunctions in the rigid
drive downtube / flexible
drive and / or shearing
handpiece.
Have fault rectified.
Shearing plant cannot
be switched off.
Switch faulty.
Have the switch replaced.
6
Environmental protection and waste disposal
6.1
Introduction
The operator bears the responsibility for disposing of the machine in the
proper manner. Observe the relevant regulations applicable in your coun-
try.
ONE Shearing Plant – Translation of the original instructions