7 Block OUTPUTS
Device Functions Proline Promag 55
76
Hauser
OUTPUT SIGNAL
(continued)
Example for active output circuit (ACTIVE):
With an active circuit, the internal power supply is 24 V.
The frequency output is short-circuit proof.
a0004691
m
= 24 V DC internal power supply
n
= Short-circuit proof output
The signal levels are to be seen as analogous to the passive circuit.
The following applies for the output configuration
ACTIVE-POSITIVE
:
In the quiescent state (at zero flow), the output signal level at the terminals is 0 V.
a0004694
In the operating status (flow present), the output signal level changes from 0 V to a
positive voltage level.
a0004692
The following applies for the output configuration
ACTIVE-NEGATIVE
:
In the quiescent state (at zero flow), the output signal level at the terminals is at a positive
voltage level.
a0004693
In the operating status (flow present), the output signal level changes from a positive
voltage level to 0 V.
a0004710
Function description
OUTPUTS
➞
PULSE/FREQUENCY OUTPUT (1 to 2)
➞
CONFIGURATION (FREQUENCY)
➀
➁
+
-
=
1 5
8 3
7
U
t
24 V
0 V
U
t
24 V
0 V
U
t
24 V
0 V
t
U
24 V
0 V
Содержание Proline Promag 55
Страница 2: ...Device Functions Proline Promag 55 2 Endress Hauser ...
Страница 5: ...Device Functions Proline Promag 55 Contents Endress Hauser 5 ...
Страница 164: ...14 Index Device Functions Proline Promag 55 164 Endress Hauser ...
Страница 166: ...www endress com worldwide BA120D 06 en 10 09 71104957 FM SGML6 0 ...