888-2406-002
4-29
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
4.5.4
Low Voltage Power Supply Board
The AC input for this board is dependant on the AC voltage and configuration for
the transmitter, 3-phase Delta (3 wire), 3-phase WYE (4 wire) or single phase. The
same board is used in all three cases. The AC inputs to the board come from circuit
breaker, CB1, and enter the board at J1-1 and J1-4. For the 3-phase Delta and Single
Phase J1-1 is Phase A and J1-4 is Phase B (Phase C for the 3-Phase does not
connect to this board). For the 3-phase 4 wire WYE J1-4 is Phase B and J1-1 is the
Neutral.Transformer T1 has dual full wave rectifiers. The T1 secondary outputs are
fused by F3, F4, F5 and F6, and are then full wave rectified for two DC outputs of
+10Vdc. The +10Vdc is filtered by C1-C6 and connected to the rectifier boards, on
top of the PA power supply transformers, in the bottom of the transmitter.
Transformer T2 secondaries are fused by F7, F8, F9 and F10 before going to dual
bridge rectifiers. The rectifier outputs are filtered by C7-C10 and 20Vdc
and -20Vdc to the Rectifier Boards on the PA power supply transformers.
All three voltages pass through the rectifier boards and are sent to the Backplane
Board to power all of the controller PC boards.
4.5.4.1 Relays
There are three mechanical relays on the Low Voltage Power Supply Board
assembly A19. They are A19K1, A19K2 and A19K3. The relays are powered by
+12Vdc from the Life Support Board in the controller.
•
A19K1 is activated when the transmitter is turned on and the
“CONTACTOR_ON” signal from the Life Support Board goes low. When acti-
vated, A19K1 supplies Phase A (or Neutral) to the coil of the AC mains contactor
K1 (and K3 in the Auxiliary cabinet for the single phase), which then supplies
AC to the PA power supply transformers.
•
A19K2 is activated by the same “CONTACTOR_ON” signal and supplies Phase
B to the exciter(s). Note that this means the exciter(s) will not have power until
the transmitter is turned on.
•
A19K3 is activated by the active low “FAN_SPEED_SELECT” signal from the
Life Support Board. A19K3 activates the fan speed select relay K2 mounted
under the AC mains contactor on the cabinet wall. K2 is shown on the Overall
System Block Diagram in the HIGH fan speed position. When A19K3 pulls in so
does K2 (not A19K2). K2 simply directs the AC to the high or low speed wind-
ings on the motor.
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...