5-24
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Maintenance and Alignment
Firmware IC Removal:
•
Shut off the Low Voltage breaker in the back of the transmitter.
•
Pull out the controller and remove the pc board hold-down bracket.
•
It will be necessary to remove the appropriate PC board and place it on an anti-
static work surface (a large anti-static bag works well if an anti-static mat is not
available). PA and PS controllers have cables attached at the rear of the card
which need to be noted and then removed.
•
Note that the PA Controllers 1 and 2 have an ID setting which means they must
be placed back in the same slot from which they were removed.
•
Before removal, notice that the IC has one corner which is beveled and the IC
socket has a pointer etched in the top which is pointing to the beveled corner. See
Figure 5-9.
•
The manufacturers do make a special extraction tool for these type of IC’s but it
has been found that a sharp meter lead or ice pick actually works better for
extracting them. Place the sharp tool point into one of the slots at the corners of
the IC pry it up just a little. Then move to the opposite corner and pry it up a little.
Work back and forth from one corner to the other until the IC comes out.
•
If the IC is going to be re-installed and you need to set it down, make sure it is
placed on an anti-static mat or in an anti-static bag.
Firmware IC Installation:
•
To install the firmware IC’s, you first need to match the U## component designa-
tor printed on the IC label with the proper socket on the board (the socket has a
label printed on the board). For example U18 and U28 are for the Master Control-
ler and must be placed in the correct socket.
•
To install the IC, simply place the chip over the socket with the beveled edge ori-
ented correctly and press it in with your thumb. Be sure to press evenly across the
top of the IC.
Figure 5-9
Top View of Firmware IC Socket
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...