888-2406-002
2-27
WARNING: Disconnect primary power prior to servicing.
Installation & Initial Turn-On
2.8
Using an Uninterruptable Power Supply or UPS
If the transmitter is backed up with a UPS, to keep it operating during an AC power
failure, then the logical thing to do is to lower the transmitter power to conserve the
UPS for as long as possible. Therefore, during an AC power failure, the transmitter
has the ability to automatically operate at a reduced power level when backed up by
a UPS or even a generator if so desired.
When the UPS is activated, TB1-9 must be pulled low. This will take the transmitter
to the preset UPS power level which is factory set for 1kW, via software in the
Diagnostics Display System. However, if the transmitter is operating in LOW
power when the UPS mode is activated, then the transmitter will stay at the LOW
power level unless the UPS level is set lower. For example, if LOW power is set for
800W and UPS is set for 1kW, the transmitter will stay at the LOW power level of
800W. If the transmitter is operating at HIGH power when the UPS mode is
activated then it will drop to the UPS power setting.
2.8.0.1 Setting the UPS Power Level
The setting of the UPS power level is done in the software of the Diagnostics
Display Menu. To set the UPS power level press [HOME, MORE,
CONFIGURATION B,D,A], see Figure 2-17. Once the new UPS power level is set
press [BACK] to save the new information. Pressing [HOME] instead will cancel
any changes made and take you back to the main menu.
Figure 2-17
UPS Power Set
[HOME, MORE, CONFIGURATION B,D,A]
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...