4-52
888-2406-002
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
a.
PA_CTRL#_MUTE. This a mute command from the PA Controller Boards
which will be triggered by various events such as a PA being removed or
inserted (# is a number from 1-4).
b.
MASTER_IPA_MUTE.
c.
FAILSAFE. Discussed earlier.
d.
PA_-15V_FAIL. This fault comes from the PA Controller Board. It is trig-
gered when there is a failure of the -15V regulator on the PA Controller. If the
-15V supply fails, the PA Controller will not be able to mute the PAs and
therefore cannot protect them, so the exciter and IPA will be muted to protect
the PAs.
e.
CONTACTOR_ON(BAR). Discussed earlier.
4.7.6.1.5 Exciter Select
Exciter Select is only applicable if the transmitter is configured with Main/Alternate
exciters. Exciter select is software controlled by the Master Controller. It can be
switched manually or will switch automatically if the active exciter fails (no RF
output). Exciter switching is done by latching relay K1. EXCITER1_SELECT is a
pulsed signal which will go high to select exciter 1. This will make U12-8 high if
the Master Controller is working (MSTR_NORMAL 1 will be high). This passes
through inverter U13-16 and RESETs K1. This places K1 in the position shown on
the schematic. K1-4 will be pulled low. This is sent two places:
a.
The low from K1-4 goes off the board to the IPA Backplane Board where it
actuates the exciter select relay, K1 to the position shown on the schematic. It
also goes to the Master Controller as a status signal, so it knows which exciter
is physically selected.
b.
The signal from K1-4 is also used to mute the off air exciter when in the Life
Support Mode, via U35-3 and U35-6, which tie into the exciter mute lines.
Exciter 2 is selected when EXCITER2_SELECT goes high which will SET K1. K1-
4 will go high and this will switch K1 on the IPA Backplane board to the exciter 2
position.
4.7.6.1.6 IPA Select
IPA select is software controlled by the Master Controller. It can be switched
manually or will switch automatically if the active IPA fails (no RF output). IPA
switching is done by latching relay K2. IPA_SELECT_1 is a pulsed signal which
will go high to select IPA 1. This will make U14-3 high if the Master Controller is
working (MSTR_NORMAL 1 will be high). This passes through inverter U13-14
and will RESET K2. This places K2 in the position shown on the schematic. K2-4
will be pulled low. This is sent two places:
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...