Overall System Theory
Figure 4-11
Simplified Single Phase Power Supply
4.4.1.3.1 Soft Start
During transmitter turn on, a fifth set of SCRs is activated (these are located on the
Rectifier Boards), See Figure 4-12. These SCRs are connected to the lowest voltage
output tap of each transformer secondary (the one with the fewest secondary turns).
However, the Soft Start SCRs are connected through a common surge limiting
resistor to ground, instead of the direct ground connection provided with the rest of
the SCRs. This allows the “Soft start” by limiting the maximum surge current while
charging the power supplies. The soft start lasts for about 6 seconds during turn on.
After the 6 second soft start the resistor is bypassed by activating the normal run-
mode SCRs which are also attached to the lowest voltage output tap but connect
directly to ground. This allows the supplies to come up to full charge. If the voltage
is not high enough, the Power Supply Controller will activate the next highest tap to
increase the voltage. It will continue this process until the DC output voltage is
approximately 52Vdc or it reaches the highest tap.
Figure 4-12
Simplified Soft-Start and Discharge, Single Phase
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...