888-2406-002
4-37
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
The Forward Factor is now used for all forward power level settings. For example,
to set the Low power control to 1kW you press the lower button. This gradually
lowers the transmitter power output by reducing the DAC_APC_REF and therefore
the APC_REF voltage and transmitter power. This in turn lowers forward power
sample and the A/D_FWD_PWR number which can be calculated at 1kW as:
A/D FWD PWR = SQRT(FWD PWR / Forward Factor)
A/D FWD PWR = SQRT(1kW / 0.003079) = 570
At an A/D FWD PWR reading of 570 the front panel Forward Power meter will
read 1kW.
4.7.2.3 APC Factor
APC_Factor is also calculated during the Forward power calibration. APC_Factor
allows the micro to calculate the necessary DAC_APC_REF number to obtain any
specific power level. For the Z2, APC_Factor is calculated as Forward calibration
power divided by the DAC_APC_REF number or:
APC_Factor = FWD PWR (kW) / DAC_APC_REF
APC_Factor = 2kW / 660 = 3.03
Once the APC_Factor is known, the controller uses this number to calculate the
DAC_APC_REF necessary to obtain the MAX HIGH, MAX LOW and UPS power
levels in the Diagnostics Display.
4.7.2.3.1 Operating APC versus Calibrated APC
There are actually 2 APC_Factors due to the fact that the directional coupler outputs
are not flat across the entire FM band. They are:
[HOME, MORE, CONFIGURATION C,A,D,C]
•
CAL_APC_Factor (Calibrated APC_Factor)
•
OP_APC_Factor (Operating APC_Factor)
The Operating APC Factor is frequency compensated based on the slope of the
coupler output and is the factor calculated above. If the transmitter is operating at
the same frequency at which it was calibrated then the two numbers will be the
same. If the operating frequency is changed, the OP_APC_Factor will be higher or
lower depending on whether the frequency went down or up compared to the
calibrate frequency. This means that if the exciter frequency is changed the
transmitter calibration can be maintained by simply changing the
OPERATING_FREQUENCY in the Diagnostics Display.
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...