888-2406-002
4-55
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
4.7.6.2.1.1 MASTER_NORMAL
This signal goes low when the Master Controller fails and only has one function. It
is the control signal for U5-13, an analog switch. The input to the switch at U5-1 is
the analog control signal, MSTR_IPA_CTL from the Master Controller APC
circuit, which controls the IPA gate voltage and therefore the power output of the
transmitter. When the Master Controller is working, the analog IPA control signal
passes through to U5-2. Provided there is no SOFTSTART_MUTE or
SYSTEM_MUTE, the IPA control signal will also pass through to U5-3 and on to
U15-3. K2 directs the IPA control signal to the active IPA.
When the Master Controller fails, MASTER_NORMAL will go low, opening the
U5-13 switch. The MANUAL PWR REF pot R25 now controls the transmitter
power output. This is factory set for 1/4 of the rated transmitter power output.
4.7.6.2.1.2 MSTR_NORMAL 1
This signal goes low when the Master Controller fails. Its primary responsibility is
to disconnect all of the control lines coming from the Master Controller via AND
gates. It causes the following actions to occur:
a.
MSTR_NORMAL 1 applies a low to AND gate U6-4, fan speed select gate.
When in Life Support Mode the fan will be forced to high speed operation
due to the possible higher than normal dissipations when running at reduced
power. The output of AND gate U6-6 passes through to U16-16 and on to the
Low Voltage Power Supply Board and the fan select relay, K3.
b.
MSTR_NORMAL 1 applies a low to AND gate U6-10. This interrupts the
SUPPLY_DISABLE command from the Master Controller to the PS Control-
ler by holding U6-8 low. The SUPPLY_DISABLE is an active high com-
mand, which is used to place the PA Power Supplies in standby mode
(standby mode is when the tap SCRs are all shut off but the discharge circuit
is not activated).
c.
MSTR_NORMAL 1 applies a low to AND gate U25-13. This inhibits the
Master Controller from giving the transmitter OFF command. The OFF com-
mand can still be given directly via the front panel overlay button or by
remote control, REM_OFF(BAR). The remote inputs REM_ON_LOW,
REM_OFF and FAILSAFE become active due to the signal
MASTER_NORMAL(BAR) going high when Life Support is initiated. This
is discussed in the paragraphs labeled MASTER_NORMAL(BAR).
d.
MSTR_NORMAL 1 applies a low to AND gate U25-2. This inhibits the Mas-
ter Controller from initiating a SYSTEM_MUTE which would mute the
exciters and the IPA.
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...