888-2406-002
3-13
WARNING: Disconnect primary power prior to servicing.
Operator Guide
NOTE:
The REF Voltage in Figure 3-13 is merely an internal reference point the con-
troller uses to reduce the wupply voltgae in optimized mode. THis reading is
usually in the low 40’s when the transmitter is optimized (well below the
actual supply voltage).
3.9
Fan Speed
The Platinum Z is equipped with a 2 speed blower. This normally runs at the LOW
speed to reduce ambient noise and increase transmitter efficiency. However, if any
fault occurs, the fan will automatically switch to high speed until the fault is no
longer active. The fan can also be forced to HIGH speed using the configuration
menus in the Diagnostics Display. See Figure 3-14. The normal setting for the fan
speed is AUTO. Pressing the [C] button toggles between AUTO and HIGH.
Figure 3-14
Fan Speed Configuration Screen
[HOME, MORE, CONFIGURATION A,D]
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...