888-2406-002
4-57
WARNING: Disconnect primary power prior to servicing.
Overall System Theory
c.
MASTER_NORMAL(BAR) applies a high to the CLEAR line of U8-3. This
enables U8-6, the Q output, to apply a 3 second SOFTSTART_MUTE after a
power failure. The POWERFAIL(BAR) signal comes from U37-7 and is a
minimum 200mSec low pulse. U37 is monitoring the +20Vdc supply and will
bring pin 7 low if the voltage drops below +12Vdc. Note that the POWER-
FAIL(BAR) signal will not go back to the high condition until 200mSec after
power is restored. In Life Support Mode, after a power failure U37-7 will go
high which triggers U8-4. This will then trigger a SOFTSTART_MUTE via
OR gate U33-10 for 3 seconds. The SOFTSTART_MUTE signal mutes the
exciter RF output, to make sure there is no RF applied to the system for at
least 3 seconds to allow the supplies to fully charge. U8 is only active in Life
Support Mode. It is cleared by the MASTER_NORMAL(BAR) signal when
the Master Controller is operational. The Master Controller normally takes
care of this function via the SYSTEM_MUTE line.
d.
MASTER_NORMAL(BAR) applies a high to the CLEAR line of U8-13.
This enables U8-10, the Q output, to apply a 3 second SOFTSTART_MUTE
whenever an on command is given via U35-11. The SOFTSTART_MUTE
mutes the exciter RF output, to make sure there is no RF applied to the system
for at least 3 seconds to allow the supplies to fully charge. U8 is only active in
Life Support Mode. It is cleared by the MASTER_NORMAL(BAR) signal
when the Master Controller is operational. The Master Controller normally
takes care of this function via the SYSTEM_MUTE line.
e.
MASTER_NORMAL(BAR) applies a high to OR gate U31-5. This circuit is
not used.
f.
MASTER_NORMAL(BAR) applies a high to OR gate U31-2. This enables
the FAILSAFE command by placing a high at U25-5, when in Life Support
Mode.
g.
Lastly, MASTER_NORMAL(BAR) applies a high to AND gates U35-2 and
U35-5. This applies a mute to the inactive exciter for as long as the transmit-
ter is in Life Support Mode. Latching relay K1 determines which exciter is
muted. K1 is shown in the RESET position, which mutes Exciter 2. When
SET, K1 will mute Exciter 1. The position of K1 cannot be changed while in
Life Support Mode.
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...