888-2406-002
5-9
WARNING: Disconnect primary power prior to servicing.
Maintenance and Alignment
5.9
Setting FWD PWR to Display 100%
This procedure simply makes the transmitter FWD PWR % meter read 100% at the
present transmitter power output (this will not change the kW reading on the FWD
PWR display). Changing TPO does not require re-calibration and is accomplished
with the following 2 steps:
STEP 1
Set the power to the desired TPO using the raise and lower buttons.
STEP 2
Go to the 100% TPO SET screen [HOME, MORE
CONFIGURATION B,A]. Set the power level to your new TPO.
Press [BACK] to update and store the new information.
The front panel FWD PWR reading should be 100%. You may also want to change
the MAX HIGH and MAX LOW power settings to something more in line with
your new TPO as well. MAX HIGH sets the maximum power level when the HIGH
ON button is pressed, while MAX LOW sets the maximum power level when the
LOW ON button is pressed.
5.10 Setting Life Support Power Level
This procedure is to be used to set the MANUAL PWR REF pot R25 on the Life
Support Board to the proper level (R25 sets the power output of the transmitter if
the Master Controller ever fails). The procedure requires an external wattmeter. If
the MANUAL PWR REF pot R25 is adjusted for any reason, the following will
assure it is set back to the proper position:
STEP 1
Adjust R25 maximum CCW.
STEP 2
Set switch S1-9 (RESET) on the Master Controller to the ON
position to place the transmitter in Life Support Mode (the fan will
switch to high speed).
STEP 3
Adjust R25, Manual PWR Reference on the Life Support Board for
500W on the external meter.
STEP 4
Switch S1-9 to OFF and the transmitter should return to your normal
TPO. It may be necessary to raise or lower power slightly.
Содержание Platinum Z2 CD
Страница 4: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 6: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 8: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 10: ...888 2406 002 WARNING Disconnect primary power prior to servicing ...
Страница 20: ...1 6 888 2406 002 WARNING Disconnect primary power prior to servicing Introduction Specifications ...
Страница 70: ...3 14 888 2406 002 WARNING Disconnect primary power prior to servicing Operator Guide ...
Страница 130: ...4 60 888 2406 002 WARNING Disconnect primary power prior to servicing Overall System Theory ...
Страница 156: ...5 26 888 2406 002 WARNING Disconnect primary power prior to servicing Maintenance and Alignment ...
Страница 194: ...6 38 888 2406 002 WARNING Disconnect primary power prior to servicing Troubleshooting ...
Страница 196: ...7 2 888 2406 002 WARNING Disconnect primary power prior to servicing Parts List ...