Chapter 2 I/O ports
-
29
-
◆
Connection example 1-3: RSF-B mini series
The figure below shows a connection example in the position control for [open collector] signals. The
command format is “2 pulse method,” and the setting values of “Parameter 11: Input function
assignment” and “Parameter 12: Output function assignment” are “0.” Note that the connection example
varies depending on the actuator.
External power
AC Servo Actuator
RSF-B mini series
White
Black
Green
Ground always
Shield
Shell
Incremental encoder
FWD inhibit
REV inhibit
Alarm clear
Ready
Speed
limiting
Alarm
In-position
Phase-A+
Phase-Z
Output
common
FWD pulse
REV pulse
+5V power supply & external resistance
R1, R2 are user’s responsibility.
Signal current should be 16mA.
AC
Power input
Transformer
Line
filter
AC/DC
power
supply
Red
Servo-ON
Deviation clear
Shield
Red
Black
White
Green
Yellow
Brown
Blue
Orange
Phase-A-
Phase-B+
Phase-B-
Phase-Z+
Phase-Z-
Encoder Monitor ground
HA-680-*B-24
Motor
Pole sensor
White
Black
Red
Green
Yellow
Brown
Blue
Orange
Shield