Chapter 7 Troubleshooting
H
- 111 -
Overload
(Alarm clear: available)
●
Description
The driver always monitors the motor current, and if the current exceeds the curve in the figure below,
the overload alarm occurs. Occurrence of the overload alarm varies depending on the actuator.
FHA-C mini AC24V type
(1)
The alarm occurs when a current of more than
1.25 times the allowable continuous current of
the actuator flows for about 170 seconds.
(2)
The alarm occurs when a current of 3 times
the allowable continuous current of the
actuator flows for about 16 seconds.
RSF supermini series(RSF-5B)
(1)
The alarm occurs when a current of more than 1.2
times the allowable continuous current of the
actuator flows for about 35(45) seconds.
(2)
The alarm occurs when a current of 2 times the
allowable continuous current of the actuator flows
for about 5(6) seconds.
RSF-8B
(1)
The alarm occurs when a current of more than
1.2 times the allowable continuous current of the
actuator flows for about 13 seconds.
(2)
The alarm occurs when a current of 1.5 times
the allowable continuous current of the actuator
flows for about 6 seconds.
HA-680過負荷アラーム検出時間
0
5
10
15
20
25
30
35
40
45
50
50
100
150
200
250
300
出力トルク[%}
検出時間[
s]
RSF-3C
RSF-5B
D
et
ec
tion
tim
e [
s]
Output torque [%] The rated torque is 100%.
RSF supermini series
Overload alarm occurrence time
0
20
40
60
80
100
120
140
160
180
200
0
50
100
150
200
250
300
出力トルク [%] 定格を100%とする
検出時間
[s
]
Output torque [%] The rated torque is 100%.
D
et
ec
tion
tim
e [
s]
FHA-C mini AC24V type
( )The inside is RSF-3C
RSF シリーズ
0
5
10
15
20
25
30
35
40
45
50
50
100
150
200
250
300
出力トルク [%]
検出時間
[s
]
RSF-14B
RSF-8B
RSF-11B
出力トルク[
%
]定格トルクを
100
%とする
RSF-B mini series
D
et
ec
tion
tim
e [
s]
Output torque [%] The rated torque is 100%.
Содержание HA-680 Series