![Harmonic Drive HA-680 Series Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/harmonic-drive/ha-680-series/ha-680-series_manual_3975415114.webp)
Chapter 6 Setting up parameters
-
108
-
No.
Description
unit
RSF-14B-30
RSF-14B-50
RSF-14B-100
00
Position loop gain
-
40
40
40
01
Speed loop proportional gain
-
120
120
120
02
Speed loop integral gain
-
20
20
20
03
Speed loop derivative gain
-
0
0
0
04
Speed feed-forward factor
-
0
0
0
05
Acceleration feed-forward factor
-
0
0
0
06
Torque command filter
-
0
0
0
07
Speed step correction
-
0
0
0
08
Torque step correction
-
0
0
0
09
Step correction switch range
pulse
4000
4000
4000
10
Control mode
-
0
0
0
11
Input function assignment
-
0
0
0
12
Output function assignment
-
0
0
0
13
Input pin logical setting
-
0
0
0
14
Output pin logical setting
-
2
2
2
15
Control input filter time costant
ms
0
0
0
16
Speed limit
r/min
6000
6000
6000
17
FWD current limiting
%
293
365
261
18
REV current limiting
%
293
365
261
19
Regenerative brake ON/OFF
-
0
0
0
20
Rotary direction
-
0
0
0
21
Allowable position deviation
pulse
30000
30000
30000
22
In-position ready range
pulse
10
10
10
23
Command pulse input factor-numerator
-
1
1
1
24
Command pulse input factor-denominator
-
1
1
1
25
Command pulse input form
-
0
0
0
26
Muliplication at 2-phase input
-
4
4
4
27
Servo-ON deviation clear
-
0
0
0
28
Angle correction
-
0
0
0
29
Auto gain setting at positioning
-
0
0
0
30
Speed command input factor
r/min
6000
6000
6000
31
Attained speed determination value
r/min
2000
2000
2000
32
Internal speed command value
r/min
1
1
1
33
Acceleration time constant
ms
1
1
1
34
Deceleration time constant
ms
1
1
1
35
Analog command A/D value (Mid)
-
4096
4096
4096
36
Analog command A/D value (Max)
-
8192
8192
8192
37
Analog command A/D value (Min)
-
0
0
0
38
Zero clamp
-
0
0
0
39
Reserved for the system
note
-
0
0
0
40
Internal command input factor
%
1
1
1
41
Torque command input factor
-
293
365
261
42
Reserved for the system
note
-
0
0
0
43
JOG operation acceleration/deceleration time
constant
ms
500
500
500
44
JOG operation feed pulse count
pulse
100
100
100
45
JOG operation S-shape selection
-
0
0
0
46
JOG operation speed
r/min
500
500
500
47
Communication setting
-
0
0
0
48
CAN ID
note
-
0
0
0
49
CAN communication speed
note
-
0
0
0
Note: This area is reserved for the system. Do not perform any setting.
Содержание HA-680 Series