Chapter 1
Outlines of the HA-680 driver
-
13
-
RSF-11B
(1)
The alarm occurs when a current of more than
1.2 times the allowable continuous current of the
actuator flows for about 23 seconds.
(2)
The alarm occurs when a current of 1.5 times
the allowable continuous current of the actuator
flows for about 10 seconds.
It is possible to clear the alarm by inputting ON signal to [CN2 Clear or Alarm clear] if it is not overload,
again.
◆
Deviation counter overflow
The alarm occurs when the value of the deviation counter exceeds the parameter setting value
(PSF-520 No.21 Allowable position deviation). This alarm can be reset by inputting an ON signal to
“CN2 Alarm Clear: ALM-CLR” after inputting an ON signal to “CN2 Clear: CLEAR” or “CN2 Deviation
Clear: DEV-CLR.”
◆
Encoder break detection
This alarm occurs when the signal from the encoder is lost. To reset the alarm, you must shut down the
power and turn it on again after diagnosing the cause.
◆
Encoder reception error
This alarm occurs when data cannot be received from the encoder successfully, or encoder signal output
cannot be performed.
◆
UVW error
An alarm occurs if encoder or pole sensor phase UVW signals become abnormal. To reset the alarm,
you must shut down the power and turn it on again after diagnosing the cause.
To clear the alarm after troubleshooting, shut off the control power once and turn it on again.
RSF-8B
(1)
The alarm occurs when a current of more than
1.2 times the allowable continuous current of the
actuator flows for about 13 seconds.
(2)
The alarm occurs when a current of 1.5 times
the allowable continuous current of the actuator
flows for about 6 seconds.
RSF-14B
(1)
The alarm occurs when a current of more than
1.2 times the allowable continuous current of the
actuator flows for about 45 seconds.
(2)
The alarm occurs when a current of 2.5 times
the allowable continuous current of the actuator
flows for about 5 seconds.
RSF シリーズ
0
5
10
15
20
25
30
35
40
45
50
50
100
150
200
250
300
出力トルク [%]
検出時間
[s
]
RSF-14B
RSF-8B
RSF-11B
RSF-B mini series
D
et
ec
tion
tim
e [
s]
Output torque [%] The rated torque is 100%.
Содержание HA-680 Series