Chapter 1
Outlines of the HA-680 driver
-
3
-
1-3 Combinations with actuators
Five HA-680 models are available for use with actuators dealing with their nominal current and encoder
systems. The correct combinations are as follows:
Model
HA-680-4-24
HA-680-6-24
HA-680-4B-24
HA-680-6B-24
Actuator model
FHA-8C
FHA-11C
FHA-14C
RSF-3C
RSF-5B
RSF-8B
RSF-11B
RSF-14B
1-4 Specifications of HA-680 drivers
Driver model
Item
HA-680-4-24
HA-680-6-24
HA-680-4B-24
HA-680-6B-24
Combined actuator
FHA-8C
FHA-11C
FHA-14C
RSF-3C
RSF-5B
RSF-8B
RSF-11B
RSF-14B
Allowable continuous
current (Arms)
note
2
1.8
3.9
6.0
0.7
1.2
2.0
5.0
4.9
Instantaneous max.
current (Arms)
note
3
3.4
8.4
16.5
1.5
2.3
3.9
15.8
17.2
Supply
voltage
Control circuit
power supply (CP)
DC24V(20~28V)
Main circuit power
supply (MP)
DC24V(20~28V)
Control method
Sinusoidal PWM control
switching frequency 12.5kHz
Encoder
4-line specification, serial transmission
method, line driver input
14-line specification
Line driver input
8-line specification
Line driver input
Pole sensor
8-line specification
Line driver input
I/O signal
DI: 5 points (insulation with phto coupler) DO: 5 points (insulation with phto coupler)
Variable function assignment
Encoder monitor
Phase-A,B,Z line driver output Phase-Z open collector output (insulation with phto coupler)
Control mode
Speed, position and torque control
Display
LED 2 points
(
green:1 point
red:1 point
)
For power on, servo-on, alarm operation state display
Speed cont
rol
Command voltage
DC0V~
±
10V/maxium speed
Input signal
FWD-enable, REV-enable, Alarm clear, Speed Command internal/external switch, Speed limiting, Current
limiting
Output signal
Attained speed, Alarm, ready, limiting speed, limiting current, Phase-Z open collector output
Speed control range
1:1000 or more
P
os
iti
on
cont
rol
Command pulse
interface
Line driver: 500kp/s(max)
open collector: 200kp/s(max)
Command
configuration
2- pulse (FWD/REV pulse train), 1 pulse method (sign+pulse train),
2-phase pulse method (90-degree phase difference 2-phase pulse train)
Input signal
FWD-inhibit, REV-inhibit, clear, Deviation clear, Speed limiting, Current limiting
Output signal
In-position, alarm, ready, limiting speed, limiting current, Phase-Z open collector output
Tor
que
cont
rol
Command voltage
DC0V~
±
10V/Max. torque
Input signal
FDW rotation start, REV rotation start, alarm clear, torque command internal/external switch, current limit
Output signal
Attained speed, alarm, operation ready, limiting current, Phase-Z open collector output
Protection function
Overload, Max. deviation, Encoder break detection, encoder reception error, UVW error, regenerative error,
operating temperature error, system error, overcurrent, load short circuit, memory error, overspeed
Connector
I/O:
3M half-pitch 26-pin
encoder: 3M half-pitch 14-pin
RS-232C: Small-type 8-pin
CAN:
RJ type
Regenerative absorption circuit Incorporated (with an external capacitor/resistor installation terminal). The built-in resistance has a fuse.
Structure
Semi-covered type (aluminum base with plastic cover)
Installation method
Base mount (wall installation)
Mass
230g
Ambient conditions
Operating temp:0~50
°
C
Storage temp:-20~85
°
C
Operating humidity/storage humidity:95%RH or less (no condensation)
No vibration or physical shock.
No powder dust, metal powder, corrosive gas, flammable gas, or oil mist.
No water or oil splashed.
To be used indoors. No direct sunlight.
Note 1: Parameter setting of this driver is performed depending on the actuator combined with it. It cannot be used
for any other actuator.
Note 2: This value may be limited depending on the combined actuator.
Содержание HA-680 Series