![Harmonic Drive HA-680 Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/harmonic-drive/ha-680-series/ha-680-series_manual_3975415022.webp)
Chapter 2 I/O ports
-
16
-
2-1-2
Assignment of output signals
Assignment of output signals varies depending on the setting value of “12: Output function assignment”
in “Parameter” as shown below. For the setting method, refer to Chapter 6 “Parameter setting.”
・
Position control, output signal assignment parameter
CN2 Pin No.
Setting value In-position
ready
Alarm
Operation
ready
Limiting
speed Limiting current
Phase-Z OC
output
0
1
2
3
4
―
5
1
1
2
3
―
4
5
2
1
2
―
3
4
5
Note: The setting value “0” is the initial setting value.
・
Speed control, output signal assignment parameter
CN2 Pin No.
Setting value Attained
speed
Alarm
Operation
ready
Limiting speed Limiting
current
Phase-Z OC
output
0
1
2
3
4
―
5
1
1
2
3
―
4
5
2
1
2
―
3
4
5
Note: The setting value “0” is the initial setting value.
・
Torque control, output signal assignment parameter
CN2 Pin No.
Setting value Attained
speed
Alarm
Operation
ready
Limiting current Phase-Z OC
output
0
1
2
3
4
5
Note: The setting value “0” is the initial setting value.
2-1-3
Type of I/O signal connector CN2
The models of the CN2 connector is as follows:
Connector: 10126-3000PE
3M
Cover:
10326-52F0-008
3M
Содержание HA-680 Series
Страница 6: ...HA 680 series servo driver manual MEMO ...