Chapter 3 Installing HA-680 driver
H
- 60 -
3-3 Location and installation
3-3-1
Environment of location
The environmental conditions of the location are described blow. Decide the location by definitely
observing the following conditions.
◆
Service temperature: 0
°
C to 50
°
C
Use the driver in a cabinet. The temperature in the cabinet may be higher than
the atmosphere because of power loss of the housed devices and its size.
Plan the cabinet size, ventilation system, and device locations so the ambient
temperature of the driver, which is always 50
°
C or less.
◆
Service humidity:
95% or less relative humidity, without condensation
Make sure that water condensation does not occur due to fluctuating
temperatures in the storage area or because of frequent heat-and-cool
(run-and-stop) operations.
◆
Vibration:
less than 5m/sec
2
(10Hz to 55Hz)
When there is a great deal of vibration near the driver, attach a shock absorber
under the base to dampen the vibration.
◆
Impact:
The location should be free from impact.
◆
Make sure that dust, water condensation, metal powder, corrosive gas, water, water drops, or oil mist
is not exposed to the HA-680 driver.
Do not install the driver in a corrosive gas environment, because the gas may
cause damage to connecting parts (connectors, etc.).
◆
Install the driver in a cabinet. Do not expose it to the sunlight.
3-3-2
Notices on installation
Install the driver vertically and allow for wide spaces for air to flow sufficiently.
Leave 30mm or more from walls, 50mm or more from floor and 100mm or more from ceiling, and
adjacent devices as shown the figure below.
When planning the ventilation system for the cabinet, refer to the table below, which lists the power
consumption of the HA-680 driver.
Driver HA-680-4
HA-680-4
HA-680-6
HA-680-4B
HA-680-6B
Actuator FHA-8C
FHA-11C
FHA-14C
RSF-3C
RSF-5B
RSF-8B
RSF-11B
RSF-14B
Power
consumption
10W 20W 40W
10W
15W 20W