Chapter 2 I/O ports
-
56
-
◆
Connection example 2: RSF supermini series
The figure below shows a connection example in torque control. The setting values of “Parameter 11:
Input function assignment” and “Parameter 12: Output function assignment” are “0.” Note that the
connection example varies depending on the actuator.
HA-680-4B-24
M
E
AC Servo actuator
Incremental encoder
Torque command
Current limit
External power
Servo-ON
Clear
FWD enable
REV enable
Line filter
Transformer
AC power
Red
Black
Green (only RSF-5B)
Always ground
Attained speed
Alarm
Ready
Phase-Z
Current limiting
AC
power
supply
Output common
Relay cable
EWA-EXX-JST09-3M14
White
7 (red) +5V
8 (black) 0V
1 (white) A
2 (green) B
3 (yellow) Z
4 (brown) U
5 (blue) V
6 (orange) W
9 FG
Phase-A+
Phase-A-
Phase-B+
Phase-B-
Phase-Z+
Phase-Z-
Encoder Monitor ground
Shell
Shell
Shield
Shield
Power Supply for Brake
DC24V for brake must be
prepared by the customer.
RSF-5B (With brake)
Relay cable
EWA-B-XX-JST03-TMC
(Brake control circuit
built-in)
RSF supermini series
Torque command common
CUR-LMT