Required Reagents
Description
Qty. required per test
Unit
Cat. No.
Acetate Buffer Solution, pH 4, w/dropper...................................................1 mL................. 100 mL ...............14909-32
Iodine Standard Solution, 0.0282 N ............................................................ varies................ 1000 mL .............23333-53
Phenylarsine Oxide (PAO) Titrant, 0.00564 N
*
.......................................... varies................ 1000 mL ...............1999-53
Potassium Iodide, SwifTest refill ................................................................0.10 g ............... 50 g.......................1077-60
Sodium Thiosulfate Standard Solution, stabilized, 0.00564 N
*
.................. varies................ 1 L ......................24088-53
Required Apparatus
Beaker, Glass, 250-mL ................................................................................ 1 ....................... each......................500-46H
Cylinder, Graduated, 250 mL ......................................................................1 ....................... each.........................508-46
Magnetic Stir Bar, Teflon
®†
coated............................................................. 1 ....................... each.....................50085-00
Pipet, Volumetric, Class A, 0.50 mL ........................................................... 1 ....................... each.....................14515-34
SwifTest dispenser.......................................................................................1 ....................... each.....................28341-00
Optional Reagents
Dilution water, organic-free ........................................................................varies................ 500 mL ...............26415-49
Potassium Iodide, Powder Pillows ..............................................................1 ....................... 100/pkg.................1077-99
Optional Apparatus
Mini-printer, thermal, w/cable............................................................................................... each.....................A70P021
*Either titrant may be calibrated with this procedure.
†Teflon is a Registered Trademark of EI DuPont Company.
Содержание AutoCAT 9000
Страница 2: ...50081_TTL fm...
Страница 8: ...Page 6 50081_Safety fm...
Страница 14: ...Page 12 50081_Introduction fm...
Страница 24: ...Page 22 50081_OperationStop fm...
Страница 34: ...Basic Operation Basic Operation Page 32 50081_Operation fm...
Страница 44: ...Page 42 50081_SoftwareSetup fm...
Страница 51: ...Calibration Procedures 50081_CalibrationStopper fm Page 49 Section 6 Calibration Procedures...
Страница 52: ...Page 50 50081_CalibrationStopper fm...
Страница 66: ...Page 64 50081_Sampling fm...
Страница 67: ...Titration Procedures 50081_ProcedureStopper fm Page 65 Section 8 Titration Procedures...
Страница 68: ...Page 66 50081_ProcedureStopper fm...
Страница 138: ...Page 136 50081_ManualEndpoint fm...
Страница 140: ...Page 138 50081_BDL fm...
Страница 154: ...Page 152 50081_Titration fm...
Страница 158: ...Page 156 50081_PrinterInstallation fm...
Страница 160: ...Page 158 50081_ReplacementParts fm...
Страница 170: ...Page 168 50081_GeneralInfoStop fm...
Страница 176: ......