![Haas Automation EC Series Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/haas-automation/ec-series/ec-series_control-book_575935035.webp)
28
January 2004
ALARMS
DISPLAY
The
ALARMS DISPLAY
can be selected at any time by pressing the ALARM / MESGS button.
When there are no alarms, the display will show NO ALARM. If there are any alarms, they will be
listed with the most recent alarm at the bottom of the list. There are three types of Alarms screens.
The first shows the currently active alarms. Pressing the RIGHT ARROW key switches to the Alarm History
screen. Pressing RIGHT ARROW again switches to the alarm viewer screen. This screen simply shows one
alarm at a time with its description (if any). The default will be the last alarm in the alarm history. The user can
then scroll through all the alarms by pressing the UP and DOWN ARROW keys. Also, the user can enter an
alarm number and press WRITE and it will be displayed. Pressing RIGHT ARROW again returns the user to the
home page of the current alarms screen. Pressing PAGE DOWN will display a page for user messages and
notes.
The CURSOR and PAGE UP and PAGE DOWN buttons can be used to move through a large number of
alarms. The CURSOR
right
and
left
buttons can be used to turn on and off the ALARM history display.
MESSAGE
DISPLAY
The
MESSAGE DISPLAY
can be selected at any time by pressing the ALARM / MESGS button a
second time. This is an operator message display and has no other effect on operation of the control.
Any message can be typed into the message display and called up later.
You may leave an electronic note to yourself or anyone else by using this feature. The note may be for the
operator to change tools after running a number of parts or it may be a diary for machine maintenance intervals.
Data is automatically stored and maintained even in a power-off state. The message display page will come up
during power-up if there are no alarms present.
To enter messages, press the ALARM / MESGS button twice. You may now enter data by simply typing
directly onto the screen. The cancel and space keys can be used to remove existing messages. The DELETE
button can be used to remove an entire line.