Operation Manual – AAA
H3C S3100 Series Ethernet Switches
Chapter 2 AAA Configuration
2-22
system is called the response timeout timer of RADIUS servers. If the switch gets no
answer within the response timeout time, it needs to retransmit the request to ensure
that the user can obtain RADIUS service.
For the primary and secondary servers (authentication/authorization servers, or
accounting servers) in a RADIUS scheme:
When the switch fails to communicate with the primary server due to some server
trouble, the switch will turn to the secondary server and exchange messages with the
secondary server.
After the primary server remains in the
block
state for a specific time (set by the
timer
quiet
command), the switch will try to communicate with the primary server again when
it has a RADIUS request. If it finds that the primary server has recovered, the switch
immediately restores the communication with the primary server instead of
communicating with the secondary server, and at the same time restores the status of
the primary server to
active
while keeping the status of the secondary server
unchanged.
To control the interval at which users are charged in real time, you can set the real-time
accounting interval. After the setting, the switch periodically sends online users'
accounting information to RADIUS server at the set interval.
Table 2-20
Set timers for RADIUS servers
Operation
Command
Remarks
Enter system view
system-view
—
Create a RADIUS scheme
and enter its view
radius scheme
radius-scheme-name
Required
By default, a RADIUS
scheme named "system"
has already been created
in the system.
Set the response timeout
time of RADIUS servers
timer response-timeout
seconds
Optional
By default, the response
timeout time of RADIUS
servers is three seconds.
Set the time that the
switch waits before it try to
re-communicate with
primary server and
restore the status of the
primary server to active
timer quiet minutes
Optional
By default, the switch
waits five minutes before
it restores the status of the
primary server to active.
Set the real-time
accounting interval
timer
realtime-accounting
minutes
Optional
By default, the real-time
accounting interval is 12
minutes.