Operation Manual – Port Basic Configuration
H3C S3100 Series Ethernet Switches
Chapter 1 Port Basic Configuration
1-8
Table 1-7
Configuring a Port Group
Operation
Command
Remarks
Enter system view
system-view
—
Create a port group or enter the
specified port group view
port-group
group-id
Required
Add an Ethernet port to a specified port
group
port interface-list
Required
Note:
z
Only S3100-EI Series Ethernet Switches support Port Group feature.
z
A port can not be added to a port group if it has been added to an aggregation group,
and vice versa.
1.1.9 Enabling the System to Test Connected Cable
You can enable the system to test the cable connected to a specific port. The test result
will be returned in five seconds. The system can test these attributes of the cable:
Receive and transmit directions (RX and TX), short circuit/open circuit or not, the length
of the faulty cable.
Table 1-8
Enable the system to test connected cables
Operation
Command
Remarks
Enter system view
system-view
—
Enter Ethernet port view
interface interface-type
interface-number
—
Enable the system to test
connected cables
virtual-cable-test
Required
Note:
z
Currently, the device is only capable of testing the cable status and cable length. For
the testing items that are currently not supported, “-” is displayed in the
corresponding output fields.
z
Cable test cannot be performed on an optical port.