Operation Manual – Information Center
H3C S3100 Series Ethernet Switches
Chapter 1 Information Center
1-10
Operation
Command
Description
Set to display the UTC time
zone in the output information
of the information center
info-center timestamp
utc
Required
By default, no UTC
time zone is
displayed in the
output information
1.2.4 Setting to Output System Information to the Console
I. Setting to output system information to the console
Table 1-7
Set to output system information to the console
Operation
Command
Description
Enter system view
system-view
—
Enable the information
center
info-center enable
Optional
Enabled by default.
Enable system
information output to
the console
info-center console
channel
{
channel
-
number
|
channel
-
name
}
Optional
By default, the switch uses
information channel 0 to
output log/debugging/trap
information to the console.
Configure the output
rules of system
information
info
-
center source
{
modu
-
name
|
default
}
channel
{
channel
-
number |
channel
-
name
} [ {
log
|
trap
|
debug
} {
level
severity
|
state
state
} ]*
Optional
Refer to
Table 1-8
for the
default output rules of
system information.
Set the format of time
stamp in the output
information
info-center timestamp
{
log | trap | debugging }
{ boot | date | none }
Optional
By default, the time stamp
format of the log and trap
output information is
date
,
and that of the debugging
output information is
boot
.
Note:
To view the debugging information of some modules on the switch, you need to set the
type of the output information to
debug
when configuring the system information output
rules, and use the
debugging
command to enable debugging for the corresponding
modules.