Operation Manual – Login
H3C S3100 Series Ethernet Switches
Chapter 2 Logging in through the Console Port
2-12
III. Configuration procedure
# Enter system view.
<Sysname> system-view
# Enter AUX user interface view.
[Sysname] user-interface aux 0
# Specify to authenticate users logging in through the Console port using the local
password.
[Sysname-ui-aux0] authentication-mode password
# Set the local password to 123456 (in plain text).
[Sysname-ui-aux0] set authentication password simple 123456
# Specify commands of level 2 are available to users logging into the AUX user
interface.
[Sysname-ui-aux0] user privilege level 2
# Set the baud rate of the Console port to 19,200 bps.
[Sysname-ui-aux0] speed 19200
# Set the maximum number of lines the screen can contain to 30.
[Sysname-ui-aux0] screen-length 30
# Set the maximum number of commands the history command buffer can store to 20.
[Sysname-ui-aux0] history-command max-size 20
# Set the timeout time of the AUX user interface to 6 minutes.
[Sysname-ui-aux0] idle-timeout 6
After the above configuration, you need to modify the configuration of the terminal
emulation utility running on the PC accordingly in the dialog box shown in
Figure 2-4
to
log into the switch successfully.