![background image](http://html2.mh-extra.com/html/h-p-cosmos/mercury/mercury_user-manual_3085347159.webp)
technical data
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc
© 2012 h/p/cosmos sports & medical gmbh [email protected] created 15.02.2012 printed 15.02.2012 page: 159 of 213
h/
p/
cosmos venu
s 200/
75
h/
p/
cosmos venu
s 200/
75 r
h/
p/
cosmos venu
s 200/
100
h/
p/
cosmos venu
s 200/
100 r
h/
p/
cosmos sat
urn 250/
75
h/
p/
cosmos sat
urn 250/
75 r
h/
p/
cosmos sat
urn 250/
100
h/
p/
cosmos sat
urn 250/
100 r
h/
p/
cosmos sat
urn 250/
125 r
h/
p/
cosmos sat
urn 300/
75
h/
p/
cosmos sat
urn 300/
75 r
h/
p/
cosmos sat
urn 300/
100
h/
p/
cosmos sat
urn 300/
100 r
h/
p/
cosmos sat
urn 300/
125 r
h/
p/
cosmos sat
urn 450/
300 rs
Dimension frame
length x width x height
2400
x1150 x
1380
2400 x
1400 x
1380
2900 x
1150 x
1380
2900 x
1400 x
1380
2900 x
1650 x
1380
3400
x1150 x
1380
3400
x1400 x
1380
3400 x
1650 x
1380
on request
dep. on
installation
Track access height from floor
(optional installation in pit)
480 mm
on request
Weight of device
850 kg
900 kg
950 kg
1000 kg
1050 kg
1100 kg
1150 kg
1250 kg
on request
dep. on
installation
Weight load limits to floors
(traffic load to DIN 1055 part 3)
9.0 kN/m²
7.5 kN/m²
7.7 kN/m²
6.5 kN/m²
5.6 kN/m²
7.0 kN/m²
5.8 kN/m²
5.1 kN/m² on request
In case of any further questions related to load limits onto floors, please ask our service department.
Max. permissible user weight on
running surface
280 kg
(deviation on request specially made)
Environmental conditions:
Transport and storage
temperature: –30...+50 °C
humidity: 0...95% - without condensation
barometric pressure: 700...1060hPa
Environmental conditions:
Operation
temperature: +10...+40 °C (deviation on request)
humidity: 30...70% - without condensation (up to 95% on request)
barometric pressure: 700...1060hPa
Maximum operating altitude: approx. 10,000 feet (3000m), without pressurization
Pollution degree
Degree 2: Normally only nonconductive pollution. Temporary conductivity caused by condensation is to be expected.
Central lubrication system
manual / running machines with [r] have automatic central lubrication system
Store program space
6 training profiles / 10 test profiles / 8 user defined profiles
RS232 Digital interface / serial port
COM1: standard; COM2: standard; COM3: optional (standard for service); COM4: optional
Heart rate measurement and heart
rate dependent endurance control
(target pulse programming)
POLAR W.I.N.D. with WearLink
coded transmission
transmission range approx. 10 m
PC software
(not for medical application)
h/p/cosmos para control
®
and h/p/cosmos para graphics
®
included
option: h/p/cosmos para analysis
®
, h/p/cosmos para motion
®
Reverse belt rotation / downhill
standard
Safety arch with harness***
option
Wheel chair stabilizer
option
Monitor arm and laptop computer
option
* Overload and weak power supply (undervoltage) could lead to higher discrepancies concerning the speed-display or dripping of the fuse. ** The time of
operation of the elevation motor (TO = 15 %) converts to approx. 5 full elevation cycles. Overload can result in temporary tripping of the fuse, but can be
used again after short cool down period. Treadmills of the h/p/cosmos saturn series built approx. before January 2007 have a maximum elevation of 25%.
*** For maximum stress tests and with oversize running machines (track sizes) a safety facility (e.g. a safety harness with chest belt) is necessary and highly
recommended. When using a front-bar handrail (crossbar), the speed is limited to 5 km/h for safety reasons. Data of weight and measurements can deviate.
Ask for further details and optional equipment or visit www.h-p-cosmos.com. Subject to technical alterations without prior notice. E & OE.