![h/p/cosmos mercury Скачать руководство пользователя страница 152](http://html2.mh-extra.com/html/h-p-cosmos/mercury/mercury_user-manual_3085347152.webp)
trouble shooting
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc
© 2012 h/p/cosmos sports & medical gmbh [email protected] created 15.02.2012 printed 15.02.2012 page: 152 of 213
[10.I1]
E52 Error
of
RS485-cable motor control
cable-defect or bad contact at the
connection MCU/frequency-inverter.
Only applicable at digital control (RS485)
of MCU5/frequency inverter
=
„E 52“
!
„FU“ flashing
§ $ %
„HELP“ flashing
The MCU5-control-boards always sends a reset-message at every
switch-on of the device. After 10 time-out-failures in a row, the MCU
generates the E52 error-message. This is equivalent to a missing
connection (e.g. cable-defect) in the cable from MCU5 to frequency-
inverter.
N
Check RS485 plug at the MCU5 control board
N
Check RS485 plug at the frequency inverter
N
Check RS485 plug at the optocoupler board
N
Contact authorized service engineer
Card Err
01
Error chip-card-drive
(not all models)
=
„CARD“
!
„ERR“
"
„1“
Running machine is still functioning (except chip card function)
N
Communication malfunction with Chip-Card
N
Insert chip-card to the chip-card-drive
N
Replace chip-card
N
Replace chip-card-drive
N
Contact authorized service engineer
Card Err
02
Error chip-card-drive
(not all models)
=
„CARD“
!
„ERR“
"
„2“
Running machine is still functioning (except chip card function)
N
Too many training weeks
N
Check period of training
N
Check system date and time settings of the running machine
N
Re-program chip-card
Card Err
03
Error chip-card-drive
(not all models)
=
„CARD“
!
„ERR“
"
„3“
Running machine is still functioning (except chip card function)
N
Test ident on the chip-card not accepted
N
False chip-card in the chip-card-drive
N
Insert the correct chip-card
Card Err
04
Error chip-card-drive
(not all models)
=
„CARD“
!
„ERR“
"
„4“
Running machine is still functioning (except chip card function)
N
unknown chip-card-malfunction
N
no card identified
N
check chip-card
N
insert correct chip-card
N
reprogram chip-card