trouble shooting
file: n:\article\cos14310m5-v1_06hpc-en\20120215_cos14310m5-v1.06hpc-en_manual_h-p-cosmos_running_machine.doc
© 2012 h/p/cosmos sports & medical gmbh [email protected] created 15.02.2012 printed 15.02.2012 page: 150 of 213
[10.I1]
E41
Error during memory initialization
SETUP ERROR“ MCU
or
low or defective battery
=
„E 41“
!
„type“
"
„OP03“
blinking
§
„SETU“
$
„P E“
%
„rrOr“ blinking
running machine is still working
N
At MCU5 control electronic (as of manufacturing date
12/2007) this error exclusively shows a defect of the option
memory (FRAM). In this case, please contact h/p/cosmos and
request a service technician.
N
Optional setup restores to default factory setting and device
type
N
By pressing the key
c
the device can still be used, but it is
likely that individual settings and program profiles may not be
available any more. Also Display readings and accuracy of
speed and elevation need to be checked.
N
Press Start and STOP, power off and power on the device.
N
In case the error message E41 is still indicated, contact an
authorized service technician.
Either the MCU electronic may be defective or the battery may be
low or defective.
E50 Error
of
frequency inverter / motor regulation
At ANALOG control of frequency inverter
=
„E 50“
!
„FU“ flashing
§ $ %
„HELP“ flashing
Running machine is not functioning
N
Check plug no. S6 at the MCU board
N
Maybe defective frequency inverter
N
Maybe power supply too weak because of an extension cable
etc.
N
Check power supply and power cord
N
Contact authorized service engineer