APS-7000 Programming Manual
80
Parameter
<NR2>
ACV level from 0V.
MINimum
Minimum voltage (0V)
MAXimum
Maximum voltage (set voltage range)
Return parameter <NR1>
Returns the surge/dip voltage (+NR1).
:SYSTem:CONFigure:SDIP:WIDTh
Set
Query
Description
Sets or queries the width of the surge/dip site.
Syntax
:SYSTem:CONFigure:SDIP:WIDTh
{<NR2>|MINimum|MAXimum}
Query Syntax
:SYSTem:CONFigure:SDIP:WIDTh?
[MINimum|MAXimum]
Parameter
<NR2>
Width in milliseconds
MINimum
Minimum width
MAXimum
Maximum width
Return parameter <NR2>
Returns the width in ms.
:SYSTem:CONFigure:TRIGger:INPut
:MODE
Set
Query
Description
Configures the mode of the rear panel trigger
input. Equivalent to the Input Pin>
Mode settings when Shift + 2[Trigger] is pressed
using the front panel controls.
Syntax
Query Syntax
:SYSTem:CONFigure:TRIGger:INPut:MODE
{<NR1>|MANual|AUTO}
:SYSTem:CONFigure:TRIGger:INPut:MODE?
Parameter
1 | AUTO
0 | MANual
Return parameter +1
+0
Example
:SYST:CONF:TRIG:INP:MODE AUTO
Sets the rear panel trigger input to AUTO.
All manuals and user guides at all-guides.com