REMOTE CONTROL
119
Questionable Status Register Group
Overview
The Questionable Status Register Group
indicates if any protection modes or limits have
been tripped.
Condition
Not Used
0
PTR/NTP
Event
Enable
OC
1
PU
2
Not Used
3
OT
4
Not Used
5
Not Used
6
Not Used
7
CAL
8
OP
9
Not Used
10
Not Used
11
Not Used
12
Not Used
13
Not Used
14
Always 0
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Questionable Status Register
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
&
Logical OR
To Status Byte Register
STATus:QUEStionable:CONDition? STATus:QUEStionable:EVENt?
STATus:QUEStionable:NTRansition <NRf>
STATus:QUEStionable:NTRansition?
STATus:QUEStionable:PTRansition <NRf>
STATus:QUEStionable:PTRansition?
STATus:QUEStionable:ENABle <NRf>
STATus:QUEStionable:ENABle?
Bit Summary
Event
Bit #
Bit
Weight
Not Used
0
1
OC (Over-Current)
Over current protection has been
tripped
1
2
PUL (Device error has occurred)
AC power switch is off
2
4
OT (Over Temperature)
Over temperature protection has
been tripped
4
16
All manuals and user guides at all-guides.com