APS-7000 Programming Manual
124
Output OFF after RMS current
limiter is activated
11
2048
RMS current limiter is operating 13
8192
Always 0
15
32768
Condition
Register
The Warning Status Condition Register
indicates the warning status of the power
supply. If a bit is set in the Condition register, it
indicates that the event is true. Reading the
condition register does not change the state of
the condition register.
PTR/NTR Filters
The PTR/NTR (Positive/Negative transition)
register determines the type of transition
conditions that will set the corresponding bit in
the Event Registers. Use the Positive transition
filter to view events that change from false to
positive, and use the negative transition filter to
view events that change from positive to
negative.
Positive Transition
0
→
1
Negative Transition
1
→
0
Event Register
The PTR/NTR Register will dictate the type of
transition conditions will set the corresponding
bits in the Event Register. If the Event Register
is read, it will be cleared to 0.
Enable Register
The Enable register determines which
registered Events in the Event Register will be
used to set the WAR bit in the Status Byte
Register.