APS-7000 Programming Manual
104
[:SOURce]:SIMulation:ABNormal:PHASe
:STARt[:IMMediate]
Set
Query
Description
Sets or queries the ON Phs parameter of the
abnormal step for the Simulation mode.
Syntax
[:SOURce]:SIMulation:ABNormal:PHASe:STARt
[:IMMediate] {<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:ABNormal:PHASe:STARt
[:IMMediate]? [MINimum|MAXimum]
Parameter/Return
parameter
<NR2>
ON Phs (start phase)
MINimum
0
MAXimum
359
Example
:SIM:ABN:PHAS:STAR 0
Sets ON Phs to 0.
[:SOURce]:SIMulation:ABNormal:PHASe
:STOP:ENABle
Set
Query
Description
Enables/Disables the OFF Phs parameter of the
abnormal step for the Simulation mode.
Syntax
[:SOURce]:SIMulation:ABNormal:PHASe:STOP
:ENABle {<bool>|OFF|ON}
Query Syntax
[:SOURce]:SIMulation:ABNormal:PHASe:STOP
:ENABle?
Parameter/Return
parameter
OFF | 0
Disabled
ON | 1
Enabled
Example
:SIM:ABN:PHAS:STOP:ENAB 1
Enable the OFF Phs.
[:SOURce]:SIMulation:ABNormal:PHASe
:STOP[:IMMediate]
Set
Query
Description
Sets or queries the OFF Phs parameter of the
abnormal step for the Simulation mode.
All manuals and user guides at all-guides.com