background image

DIN-00021-A               10-12

CN-3600SE

 

Instruction Manual

CN-3600SE

For additional information refer to the Quick Start 
Guide, included with product packaging.

www.furmancontractor.com

16 A Maximum

For more information call: 
Para más información llame al:
Pour plus de renseignements: 

877-486-4738

                                                                        

CONTRACTOR SERIES SmartSequencer

Содержание CONTRACTOR Series

Страница 1: ... For additional information refer to the Quick Start Guide included with product packaging www furmancontractor com 16 A Maximum For more information call Para más información llame al Pour plus de renseignements 877 486 4738 CONTRACTOR SERIES SmartSequencer ...

Страница 2: ... due to line sags and brown outs This means that inrush currents are offset in time rather than occurring simultaneously This can also be advantageous to upstream equipment if the sequencer is supplementing other power management such as a UPS or voltage regulator The Furman Contractor CN 3600SE provides three delay stages Each stage is independently fused and protected If three stages of power se...

Страница 3: ...an contractor devices to be linked together and controlled up to distances of 300 Meters about 1000 feet SmartSequencing devices can be chained to gether to form a network of sequencers A maxi mum of 99 SmartSequencers can be linked to gether to form a SmartSequencing network that spans a distance of 30 KM 18 2 Miles SmartSequencing devices can be connected to gether without regard for polarity wi...

Страница 4: ...NEGATIVE 12VDC RETURN PIN 2 TRANSMIT DATA PIN 3 RECEIVE DATA PIN 4 ACCESSORY POWER ONLY PIN 5 SIGNAL GROUND PIN 6 ACCESSORY POWER ONLY PIN 7 REQUEST TO SEND PIN 8 CLEAR TO SEND PIN 9 ACCESSORY POWER ONLY POSITIVE 12V DE 9 FEMALE CONNECTOR RS 232 DELAY 3 OUTLET BANK Rear LED Indicates unit is receiving AC power and Unswitched outlets are active DE 9 Communications port can also provide power Pin 2 ...

Страница 5: ...tSequencing technology provides a very simple means of connecting together a group of Furman Contractor devices to form a network or chain of sequencers SmartSequencing al lows all devices within a chain to be controlled and queried from a single Primary sequencer One of the defining characteristics of SmartSe quencing technology is its ability to allow any one to quickly achieve professional resu...

Страница 6: ... set these switches in any posi tion you like to achieve your preferred time de lay The table below summarizes the settings of DIP switch positions 1 2 3 and corresponding maximum time delay Example If the DIP Switches are set to a 6 min ute maximum time delay and the DLY ADJ is set to its 50 setting then the delay interval be tween sequenced banks will be 3 minutes DIP 1 OFF or DOWN DIP 2 and DIP...

Страница 7: ...utton is pressed and then open again when the button is released Momentary switching allows multiple push button switches to be connected in parallel with the REM input This allows the CN 3600SE to be toggled ON or OFF from mul tiple locations DIP 5 DIP 6 Outlet behavior as a function of the REM signal input OFF OFF Outlet is deactivated when REM is connected to 12VDC ON OFF Outlet is activated wh...

Страница 8: ... GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 ON MNT SEC MANUAL 6 7 8 9 9 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2...

Страница 9: ...configured to au tomatically clear EVS errors DIP Switch 9 ON this LED will turn off approximately 5 seconds after the incoming line voltage has returned to normal If the unit is configured for manual EVS recovery DIP Switch 9 OFF this LED will remain illuminated Red until the EVS error has been manually cleared See page XXX for further details The 16A front panel breaker provides an overall curre...

Страница 10: ... 3600SE The GND terminal pin serves a ground reference point for all other pins on the remote terminal connector GND is also intended to be fed back into the REM pin when the CN 3600SE is config ured for GND ON mode This is explained in detail in section DIP 5 and 6 Remote Input Setting on page 6 Pin Label Description 1 12V General purpose 12VDC output 12 mA 2 STAT Status output intended to drive ...

Страница 11: ... the foregoing section and press the SEQUENCE START button or turn the Key Switch to the ON position Multiple Unit Set Up If you plan to use more than one CN 3600SE sequencer in a SmartSequencing network or chain the factory default DIP Switch settings will be correct for the first Primary unit only Subsequent downstream CN 3600SE s will need to be configured as Secondary devices To do this you wi...

Страница 12: ... S S 12 STAT REM GND UNIT 2 SECONDARY INTERFACE NO NC C FORCE OFF FORCE OFF FORCE OFF FORCE OFF FORCE OFF FORCE OFF FORCE OFF FORCE OFF NO NC C CN 3600SE CN 3600SE CN 3600SE ON 1 2 3 4 5 6 7 8 9 SECONDARY DIP SWITCH SET SYSTEM CONTROLLER RS 232 PROTOCOL CN 3600SE 12 STAT REM GND System controllers can interface with the CN Series sequencers locally or from the cloud Yet also be interrupted by fire...

Страница 13: ... tinguish as soon as voltage returns to normal If the EVS is set to MANUAL the EVS error will need to be manually cleared Please refer to section XXX on page YYY for details on how to clear the EVS error 9 My sequencers are out of sync Sequencers can fall out of sequence if one or more sequencers experience a power failure or an EVS condition When this happens the sequencer will normally remain of...

Страница 14: ...x type 5 Pin Connector with Screw Terminals FORCE OFF DELAY 3 32VDC at 100mA Max RS 232 Compatible DE 9 Connector IP Addressability Optional via BB RS232 Ethernet RS 232 Adaptor sold separately for IP control via BlueBOLT Voltmeter Available with RS 232 and other options 1VAC accuracy Ammeter Available with RS 232 and other options 0 3 A accuracy 4 Thermal Circuit Breakers pushbutton Power Consump...