APS-7000 Programming Manual
112
[:SOURce]:SIMulation:NORMal<1|2>
:PHASe:STOP[:IMMediate]
Set
Query
Description
Sets or queries the OFF Phs parameter of the
normal1 or normal2 step for the Simulation mode.
Note:
Sets the off phase of the waveform after the output
has been turned off.
Syntax
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STOP[:I
MMediate] {<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STOP[:I
MMediate]? [MINimum|MAXimum]
Parameter/Return
parameter
<1|2>
Normal 1 or Normal 2
<NR2>
OFF Phs (Stop phase)
MINimum
0
MAXimum
359
Example
:SIM:NORM1:PHAS:STOP 0
Sets OFF Phs to 0.
[:SOURce]:SIMulation:NORMal<1|2>:TIME
Set
Query
Description
Sets or queries the Time parameter of the normal1
or normal2 step for the Simulation mode.
Syntax
[:SOURce]:SIMulation:NORMal<1|2>:TIME
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:NORMal<1|2>:TIME?
[MINimum|MAXimum]
Parameter/Return
parameter
<1|2>
Normal 1 or Normal 2
<NR2>
Time of the step in seconds
MINimum
0
MAXimum
99.99s
Example
:SIM:NORM1:TIME 1
Sets the step time to 1 second.