APS-7000 Default Settings
The following default settings are the factory configuration settings
for the power supply.
For details on how to return to the factory default settings, please
see the user manual.
Continuous Mode
APS-7050
APS-7100
Range
155V
ACV
0.00V
FREQ
60.00Hz
IRMS
4.20A
8.40A
ON PHS
0º
OFF PHS
0º
V limit
155.0Vrms
F Limit
500.0Hz
Ipeak Limit
16.80Arms
33.60Arms
Simulation Mode
APS-7050
APS-7100
Step
Initial
Repeat
1
Time
0.10s
ON Phs
ON, 0
Vset
0.00
OFF Phs
ON, 0
Fset
50.00
Trig Out
LO
Range
HI