REMOTE CONTROL
79
Syntax
:SYSTem:CONFigure:SDIP[:MODE]
{<NR1>|DISable|MANual|AUTO }
Query Syntax
:SYSTem:CONFigure:SDIP[:MODE]?
Parameter
0 | DISable
Disables surge/dip mode.
1 | MANual
Sets the surge/dip mode to
manual.
2 | AUTO
Sets the surge/dip mode to auto.
Return parameter <NR1>
+0
Surge/dip mode off.
+1
Manual mode.
+2
Auto mode.
:SYSTem:CONFigure:SDIP:SITE
Set
Query
Description
Sets or queries the surge/dip site (equivalent to the
T1 time setting using the panel controls).
Syntax
:SYSTem:CONFigure:SDIP:SITE
{<NR2>|MINimum|MAXimum}
Query Syntax
:SYSTem:CONFigure:SDIP:SITE?
[MINimum|MAXimum]
Parameter
<NR2>
Site number 0 ~99
MINimum
Minimum site 0
MAXimum
Maximum site 99
Return parameter <NR1>
Returns the site in msecs (+NR1).
:SYSTem:CONFigure:SDIP:VOLTage
Set
Query
Description
Sets or queries the surge/dip voltage level.
Syntax
:SYSTem:CONFigure:SDIP:VOLTage[:LEVel][:AMPLitud
e] {<NR2>|MINimum|MAXimum}
Query Syntax
:SYSTem:CONFigure:SDIP:VOLTage[:LEVel][:AMPLitud
e]? [MINimum|MAXimum]
All manuals and user guides at all-guides.com