GST GST200 Скачать руководство пользователя страница 1

 

 

Содержание GST200

Страница 1: ......

Страница 2: ...ernal Structure 6 3 1 1 Display Area 7 3 1 2 Description of LEDs 7 3 1 3 Description of Keys 8 3 1 4 Zone Indication and Manual Interventional Panel ZCP 9 3 2 Configuration 10 3 2 1 Standard Configuration 10 1 1 2 Optional Units 10 3 3 Periphery Devices 11 3 3 1 A Series of Intelligent Fire Detectors 11 3 3 2 Modules 11 3 3 3 Loop Isolator 12 3 3 4 Manual Call Points 12 3 3 5 Sounder Strobes 12 3 ...

Страница 3: ...ncing the panel 32 6 3 Instructions for Operator Operator Password Required 32 6 3 1 Resetting the system 32 6 3 2 Enable and Disable 33 6 3 3 Operation through STAR STOP Key 35 6 3 4 Operation of the Devices by ZCP 36 6 3 5 Setting work mode of printer 37 6 3 6 Checking all visual and audible indications 37 6 3 7 Gas Extinguishing Equipment 37 6 3 8 Burglar Mode Setting 37 6 4 Instructions for Sy...

Страница 4: ... the installation Consult with the appropriate Authority Having Jurisdiction AHJ for confirmation of the requirements GST200 Fire Alarm Control Panel FACP shall only be installed and serviced by trained specialist Disconnect all sources of power before servicing Control unit and associated equipment may be damaged by removing and or inserting cards modules or interconnecting cables while the unit ...

Страница 5: ...fire alarm devices 7 8 Outputs Output to automatic fire protection equipment 7 10 The power supply of GST200 FACP complies with EN 54 4 requirements EN 54 AC DC 100W Power Supply Functions EN 54 4 Clause Derive Power supply from main source 5 1 Derive Power supply from a standby power battery 5 2 Charge and monitor the standby battery source 5 3 Detect signal power supply faults 5 4 In addition to...

Страница 6: ...detector I 9103 complying with EN 54 5 intelligent manual call point I 9202 complying with EN 54 11 intelligent reflective beam detector I 9105R complying with EN 54 12 input and output module I 9300 I 9301 complying with GEI 1 084 and loop isolator C 9503 complying with GEI 1 052 3 The LCD can display 8 lines in total and 18 characters each line assisting the 15 LEDs to display important informat...

Страница 7: ...FP200 FLEX 2 core and Earth 1 5mm2 CSA 2 3 Communication Loop Parameters 2 3 1 RS 485 Communication Loop NETWORK A B Communication cable for connecting with up to 32 network FACPs REPEATER A B Communication cable for connecting with up to 10 repeater panels Recommended Wiring subject to local installation codes GST FireCable 2E 1 0 2 core and Earth 1mm2 CSA Pirelli Cable Limited FP200 FLEX 2 core ...

Страница 8: ...rth 1mm2 CSA Recommended Cable Length 1000m 2 5 Output Loop Parameters Recommended Wiring subject to local installation codes GST FireCable 2E 1 0 2 core and Earth 1mm2 CSA Pirelli Cable Limited FP200 FLEX 2 core and Earth 1mm2 CSA Recommended cable length 1000m 2 5 1 FIRE ALARM OUTPUT Output Voltage 21VDC 27VDC Output Current 0mA 500mA End of Line Resistor 4 7kΩ 1 1 1 F P E OUTPUT Output Voltage ...

Страница 9: ...nce and internal structure are shown in Fig 3 1 and 3 2 1 7 6 5 4 3 2 Fig 3 1 1 Clock 2 LCD 3 Printer panel 4 Optional units 5 LED 6 Keypad 7 Zone indication and manual intervention panel ZCP Fig 3 2 1 Display control main board switch board LCD 2 Zone indication and manual intervention panel ZCP 3 Printer 4 Optional units FCP fireman s control panel 5 Speaker 6 Power supply 7 Loop interface board...

Страница 10: ...ed MUTE Yellow It illuminates when the FACP is in mute state It goes out only when new alarm sound comes AC FAULT Yellow It illuminates when 230VAC power is down or damaged After the AC power resumes it goes out automatically SYSTEM FAULT Yellow It illuminates if the program encounters a dead halt After the system is rebooted only by pressing RESET can system fault be cleared and this LED goes out...

Страница 11: ... required SELF TEST Pressing this key in standby state can test the visual and audible indication of the panel operator password required MODE Setting the panel to automatically start the gas extinguishing equipment or not operator password required START STOP Start stop the loop devices operator password required ENABLE DISABLE Enabling disabling addressable devices and delay mode TAB SEC For set...

Страница 12: ...mplete the following functions through defining 3 1 4 1 Zone Indication LEDs Fire Red It illuminates when a fire occurs in a zone It goes out after the FACP is reset Fault Disable Yellow It flashes when there is any fault with the zone If all devices in this zone have been disabled the LED illuminates steadily It goes out after the fault conditions are cleared or the FACP is reset The key of a zon...

Страница 13: ...ire alarm system Power supply It provides power to the main board loop interface board and printer Its backup feature ensures that devices registered during commission will not be lost in case of power fault Display and operation part This part is used to indicate and display different status of the system and enables relative operations through keypad browsing setting printing and etc Zone indica...

Страница 14: ...D which lights on receiving signals 3 Green LED which lights on sending signals 4 RS 485 network communication cable A and B 5 20P data cable connecting with main board 6 Standard RS 232 interface connecting with GMC Note You need to include a RS 232 card in your first order of GST200 Only with this card device definition and C E equations can be downloaded from PC 3 3 Periphery Devices 3 3 1 A Se...

Страница 15: ...MCP and sound alarm 3 3 5 Sounder Strobes Addressable sounder strobe is a kind of audible visual alarm device installed in the protected area which can be activated by the FACP at the fire control center or by manual call points A series of GST addressable sounder strobes such as I 9403 can be connected to the loop of GST200 After activated it will generate strong audible visual alarm signal 3 3 6...

Страница 16: ...heck the configuration according to packing list The main items to be examined are installation and operation manual keys to the FACP etc Check Internal Configurations and Interconnection of the FACP All internal parts have been connected including optional units ordered before the FACP leaves the factory Therefore you can mainly check the zone indication and manual intervention panel and power su...

Страница 17: ...evice state in zone indication and manual intervention panel are illuminated in turn Check if the speaker can give four kinds of obvious loud alarm sounds 4 4 Connections of Field Devices 4 4 1 Connection of AC Power GST200 Fire Alarm Control Panel receives power from a 230V 50Hz supply The current flows through a filter to the transformer The transformer converts the input mains voltage to 27VAC ...

Страница 18: ...rminal P4 P4 P4 Fig 4 2b Note Do not make the final battery connections until the installation is complete 4 4 3 Connection of Field Devices Caution Do not connect power to your device until you have completed all input and output connections Failure to do so may result in injury GST200 connects with field devices by loop interface board Terminals of loop interface board are shown in Fig 4 3 LOOP ...

Страница 19: ...d should give fault signals when connected circuit is shorted or opened LOOP BUS XT2 XT4 Class A loop can connect with up to 235 addressable devices With loop isolator in Class A loop the detector protected by loop isolator is not missing when there is short or open circuit In this case the FACP reports loop fault RS 485 XT11 XT12 To be connected with repeater panel and FACP earth X8 This terminal...

Страница 20: ...ine Resistor 4 7kΩ Diode Diode F P E F P E OUTPUT XT6 A 4 7kΩ resistor is connected at the F P E OUTPUT XT6 as factory default Please remove it and keep it well before connection Connect the loop in correct polarity and add the resistor to the end of the line NOTE F P E are polarity sensitive Note polarity in connection The maximum current of the circuit depends on the number of F P E Do not overl...

Страница 21: ...onnection of Communication Loop Fig 4 8 4 5 Connection Inspection and Device Registration 4 5 1 Connection Inspection Check the circuit connected with the FACP Measure the insulation resistance between loops and between loops and ground which should be more than 20MΩ Measure the load of detection loops which should be more than 1kΩ The resistance between cables of FIRE ALARM OUTPUT SOUNDER CIRCUIT...

Страница 22: ...nce with the project design and remove any problems 4 6 Device Definition Please define devices and C E equations by the software GstDef2 0 Defining Tool through a PC and download the definitions to the FACP Refer to GstDef2 0 Defining Tool User s Manual for detailed operation 4 7 Field Device Commission After connection definition and download of device and C E equations you can power up the FACP...

Страница 23: ...abnormal information 5 1 Normal Information The normal display is shown in Fig 5 1 which means the system is in working state Then only POWER HEALTHY LED lights Fig 5 1 Fig 5 2 shows the system is in normal operation but with disabled devices Pressing VIEW DISABLE can browse these devices Fig 5 2 5 2 Fire Alarm 5 2 1 Fire Alarm Screen FIRE LED is lit when there is fire alarm signal Speaker of the ...

Страница 24: ...t fire alarm 2 Fire alarm screen for loop display mode is shown in Fig 5 4 Fig 5 4 001 0f 006 FIRE 05 25 Zone 001 030MCP Device 30 Last Fire Zone 003 Z 003 Device 066 001 0f 006 FIRE 05 25 There are six devices with fire alarm signals and this is the first Zone 001 030MCP The number of zone with fire alarm and type and address of the device in fire alarm Device 30 Description of device in fire ala...

Страница 25: ...ports battery fault if the battery voltage is lower than 18 9V and would Light COMMON FAULT and BATTERY FAULT LED The LCD displays Bat Fault The panel generates fault sound Fault relay outputs System fault The panel would report system fault if its control CPU and circuits is in fault and the panel cannot work normally It lights the COMMON FAULT and SYSTEM FAULT LED There is no display on the LCD ...

Страница 26: ... fault If there is trouble with one of the field devices the panel reports fault with it and The panel lights the COMMON FAULT LED The corresponding ZCP LED flashes The panel generates fault sound Fault relay outputs The LCD displays the fault message The fault screen is as in Fig 5 5 in zone display mode and as in Fig 5 6 in loop display mode Fig 5 5 001 0f 002 FAULT10 18 Zone 003 floor3 Office3 ...

Страница 27: ...e fault can t be cleared for some reason and enable it when the fault is removed 5 4 Rules for Message Display If there are multiple messages in the system they will be displayed in the following order fire alarm action fault start disable 1 The earliest fire alarm is displayed in priority The latest action fault disabled message is displayed in priority 2 There are zone and loop display modes for...

Страница 28: ...r to move the cursor to modify any character Pressing TAB the highlight moves to the next position and returns to the first after the last position Wherever the cursor is Pressing ENTER key all the input data will be saved If there is no keypad operation for over 1 minute the system will exit present state without saving the input data 6 1 3 Unlocking and Locking the Keypad Unlocking the Keypad Th...

Страница 29: ...ing more than one piece of message The current information is highlighted when there is more than one piece of message on the LCD You can view details of this item by pressing ENTER or exit by pressing ESC When the printer is set as All History mode pressing PRINT while browsing can print the current displayed message 6 2 2 3 Setting LCD contrast and viewing C E equation Pressing SCREEN the system...

Страница 30: ...number 3 you can enter the screen for browsing C E equation as shown in Fig 6 6 The highlighted line is the current message Pressing or can choose a piece of message Pressing ENTER then the details of this message will be displayed Pressing ESC will exit the operation ENTER Browse C E Sum 003 C E 001 C E 002 C E 003 Browse C E C E 001 G0100103 G0100203 G0100203 G0100303 G0100103 G0100303 G0100103 ...

Страница 31: ... into effect Asterisk wildcard represents any number used in special conditions Event It is the message generated by the FACP when there is fire alarm or action of device A result is composed of the following items 01 6 2 2 4 Browsing registered devices Pressing BROWSE can enter the screen for viewing registered devices as shown in Fig 6 7 Fig 6 7 Input number 1 you can view loop devices The displ...

Страница 32: ...cation NO 001 Optical address and type of the device Sensitivity Nominal property of the device Office1 Description of device location 2 Loop display mode is shown in Fig 6 9 The present message is highlighted and can be chosen by pressing or Pressing ENTER can browse further messages and ESC for exiting Browse Sum 012 NO 001 Optical NO 002 Optical NO 003 Optical NO 004 Sounder Browse Zone 01 offi...

Страница 33: ...O 03 004 Sounder Define key No 3 as sounder whose start up address is 004 6 2 2 5 Browsing history log Pressing LOG the FACP enters the state of browsing history record Using and you can browse every item the screen is shown in Fig 6 11 History Record NO 200 FIRE TIME 10 23 14 08 Zone Name 121 Optical Fig 6 11 NO 200 The two hundredth history log FIRE Fire alarm message TIME 10 23 14 08 Date and t...

Страница 34: ...01 There are three disabled devices in the system and this is the first Zone 001 004Sounder The zone number address and device type of the disabled device Office1 Description message of the disabled device Fig 6 13 001 of 002 Disable 12 01 Zone 005 Z 005 029 029 Zone Fully Disabled 001 of 002 Disable 12 01 There are devices from 2 zones that are disabled and this is the first zone Zone 005 Z 005 Z...

Страница 35: ...n Office1 Description message of the device in action 6 2 3 Silencing the panel Pressing MUTE can stop the sound of speaker pressing MUTE again the FACP is still in mute state It will sound by priority when new event appears If the conditions for silencing the system is met fire alarm silence delay settings and correct operation password level the system can also be silenced 6 3 Instructions for O...

Страница 36: ... 6 16 Disable Enable 1 Disable Devices 2 Enable Devices 3 Dis En able Delays Fig 6 16 6 3 2 1 Disabling a Device In the screen shown in Fig 6 16 input number 1 you can enter disable screen as shown in Fig 6 17 where you are able to disable devices The panel provides two methods for disabling devices You can disable a single device single device disable or all devices of a zone or multiple devices ...

Страница 37: ...isable sounder circuit output by inputting in sequence the zone number 000 device type 240 and device type 55 The panel will light the SOUNDER FLT DISABLE LED You can disable F P E output by inputting in sequence the zone number 000 device type 241 and device type 65 The panel will light the F P E FLT DISABLE LED 6 3 2 2 Enabling Devices In the screen shown in Fig 6 16 input number 2 you can enter...

Страница 38: ...3 3 Operation through STAR STOP Key Pressing START STOP can start or stop loop devices as shown in Fig 6 20 Fig 6 20 Start Stop 1 Start Devices 2 Stop Devices 3 View Start 4 View Delay 6 3 3 1 Starting Loop Devices In the screen shown in Fig 6 20 you can enter loop device start screen by entering number 1 as shown in Fig 6 21 Similar to disabling devices you can also start a single device or multi...

Страница 39: ...being started 6 3 3 4 Viewing delayed devices In the screen shown in Fig 6 20 you can view delayed devices by entering number 4 as in Fig 6 24 Fig 6 24 001 of 001 Delaying 10 Zone 001 004Sounder Office1 001 of 001 Delaying 10 There are totally one device being delayed and this is the first The left delay time is 10 seconds Zone 001 010Sounder The zone number device address and device type of the d...

Страница 40: ...PRINT 6 3 6 Checking all visual and audible indications In normal monitoring state you can check all visual and audible indications of the FACP by pressing SELF TEST 6 3 7 Gas Extinguishing Equipment Pressing MODE you can set up gas extinguishing equipment The screen is shown in Fig 6 26 Fig 6 26 Extinguish 1 Disable 2 Enable Entering 1 means not to start gas extinguishing equipment by C E automat...

Страница 41: ...f time Its window is shown in Fig 6 28 BURGLAR ON OFF TIME Please Input 00 00 ON 00 00 OFF Fig 6 28 If you input 19 at highlighted position then press TAB and input 30 the ON time of burglar mode is 19 30 Pressing TAB again you can set up the OFF time Input 07 press TAB then input 30 again the OFF time is 07 30 Pressing ENTER to confirm and the system returns to the setting screen 6 4 Instructions...

Страница 42: ...te Setting Please Input Day Month Year 04 01 05 Hour Minute Sec 11 39 55 Fig 6 30 6 4 2 Modifying Password Inputting 2 on the screen in Fig 6 29 the system enters the window of password modification See Fig 6 31 Now the passwords can be modified Fig 6 31 Password Change 1 Operator Password 2 Manager Password Input 1 or 2 to choose password to be modified the system enters the window in Fig 6 32 Fi...

Страница 43: ...display the window shown in Fig 6 34 meaning the modification is successful GST CO LTD Success Fig 6 34 6 4 3 Network Setup Input 3 on the screen in Fig 6 29 the screen shown in Fig 6 35 will be displayed Fig 6 35 NETWORK SETUP 1 NET Local Address 2 NET Event Display In the above screen You can set the panel s network address by entering number 1 as shown in Fig 6 36 Fig 6 36 Net Local Address Ple...

Страница 44: ...fter inputting the number of zones in the network on highlighted position press ENTER to confirm and return The zone numbers of the FACP will start from this number For example if the beginning number is 003 then the FACP zone number will be 003 004 005 in sequence Fig 6 38 Net Zone Number Please Input 001 6 4 5 Customized Setup Input number 5 in the screen shown in Fig 6 29 will enter customized ...

Страница 45: ...ed in Section 6 3 2 4 is set to Enable 6 4 5 1 2 C E Outputs Entering number 2 in the screen in Fig 6 40 will choose 2 C E Outputs to set Sounder A F P E and the zonal sounders to output according to C E equation and The above described Default Output will be disabled Sounder A F P E and zonal sounders need to be included into the C E equation and Sounder A F P E and zonal sounders will start subj...

Страница 46: ...Input 7 on the screen shown in Fig 6 29 to enter the window shown in Fig 6 43 Entering the equipment number and the order number can view the supervisory value of addressable devices Fig 6 43 GST CO LTD Equipment Num 001 Order Number 002 Pressing different number keys represent different commands 0 represents the command Polling If the displayed value is between 450 650 the device is in normal ope...

Страница 47: ...aded IQmin 0 42A is the quiescent current when the FACP is with no load ILmax 0 3A is the maximum loop current IFout 0 5A 3 1 5A which is the alarm output current The FACP provides 3 fire alarm outputs output current of each is 0 5A T1 is the monitoring time when the FACP is full loaded which shall be at least 24 hours according to EN 54 4 T2 is the alarm time which shall be at least 30 minutes ac...

Страница 48: ...Sealed lead acid battery Recommended period for replacing the battery 5 years 25 Recommended manufacturer and model Yuasa NP17 12I Disposal of used batteries Please properly dispose the used batteries according to your local rules and regulations NOTE RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE 8 2 Replacing the Fuses Table 8 1 Location Mark Rated Value Power filter F7 820 323 F1...

Страница 49: ...the batteries 4 Unable to register loop equipment Bus wrong or loose connection Check the loop 5 Unable to register repeater panels Wrong or loose connection of communication cables Check power supply to repeaters and communication wires 6 Cannot print a Print mode is not set b Loose connection with printer c Printer damaged a Set the print mode b Check and connect the printer well c Replace the p...

Страница 50: ...ation and Operation Manual The Intelligent Solution Page 47 Appendix 1 Internal Connection Diagram Connecting with the cabinet 1 Main Board 2 Switch Board 3 LCD 4 Printer 5 Speaker 6 Loop Interface Board 7 Power Board 8 Transformer 9 Power Filter 10 ZCP ...

Страница 51: ...Water flow indicator MCP 11 Manual call point VA Module 12 Voice alarm module Sounder 13 Sounder strobe FTModule 14 Fire telephone module HR MCP 15 Hydrant pump HR Pump 16 Hydrant pump SPKR Pmp 17 Sprinkler pump PS SW 18 Stabilized pressure pump Extract 19 Smoker exhauster Presuriz 20 Blower FreshAir 21 Fresh air Damper 22 Fire damp SM Vent 23 Smoke vent AirInlet 24 Air inlet SolValve 25 Solenoid ...

Страница 52: ... supply unit EM Light 45 Emergency light EscapeLT 46 Escape light GasActiv 47 Gas activation Security 48 Security module ZoneValv 49 Zone valve Cylinder 50 Cylinder DelugePM 51 Deluge pump NoDefine 52 Undefined STOP MOD 53 Device stop SILENCE 54 Silence key SOUNDERA 55 Fire alarm sounder SOUNDERF 56 Fault sounder Loop SW 57 Loop switch NoDefine 58 Undefined Loop 59 Loop PSU Bat 60 Associated batte...

Страница 53: ...tions for silencing the system is met fire alarm silence delay settings and correct operation password level the system can also be silenced VIEW FAULT Viewing fault information when in non fault state SELF TEST Audible visible self test key In normal monitoring state you can check all the audio visible devices by pressing this key password required LOCK When keypad is in unlocked state press this...

Страница 54: ...first fire alarm Disable Enable Disable Password No access password is required Disable Page 51 Enable Initialize System System initialization Device Debug Viewing the supervisory value of addressable devices ENTER Confirming the input is valid In monitoring state press this key to change time display between month day and hour minute modes VIEW PLANT Press this key to display action information w...

Страница 55: ...le Devices Enable Devices Re enabling disabled devices Dis En able Delays Setting delay mode SEC Setting security mode password required Disable Burglar mode is invalid The system doesn t respond to the action of security modules Enable The burglar mode is enabled The system responds to the action of security modules Only Night Burglar mode is only effective during night The screen shows a request...

Страница 56: ...om cn GST UK Global System Technology PLC Lion Court Staunton Harold Hall Melbourne Road Ashby de la Zouch Leicestershire England LE65 1RT Tel 44 1283 225 478 Fax 44 1283 220 690 Email info gst uk com www gst uk com GST Dubai Global System Technology PLC P O Box 17998 Unit ZA04 JEBEL ALI Free Zone Dubai UAE Tel 971 0 4 8833050 Fax 971 0 4 8833053 Email info gst uk com www gst uk com ...