8 Smart Climate 310 rev. 03
Probe Connection Precautions
Each probe can be extended up to 500 feet (150 meters). The
following are precautions to follow when working with probes:
IMPORTANT:
use an 18 AWG or more, shielded cable of
outside diameter between 0.245 and 0.260 in (6.22 and 6.60
mm) to ensure the cable entry is liquid tight.
NOTICE
: Do not ground the shielding.
NOTE
: Solder the cable joint to ensure a proper contact
between the two cables.
CAUTION:
Do not run probe cables next to other power cables.
When crossing over other cables, cross at 90°.