Smart Climate 310 rev. 03 23
Automatic Relay Assignment
The controller automatically assigns a relay to each on/off stage
that is enabled in the
User Setup
menu. The table below shows
how the relays are assigned for each possible stage combination.
* On/off fan relays are assigned in numerical order: the first stage
uses relay 1, the second stage uses relay 2, etc. However, the first
On/off fan stage does not correspond to stage 1 but to the stage
number that follows the last variable fan stage.
For example, if fan stage 2 is used for minimum ventilation, the first
on/off fan stage is fan stage 3 and it uses relay 1.