74 Smart Climate 310 rev. 03
Selecting the Maximum Opening Mode
Select the proper maximum opening method: dumping /
progressive. Refer to previous graphs.
To select the maximum opening mode, proceed as follows:
1. Select the desired air inlet: AIR INLET 1, AIR INLET 2 or
0-10v Output
(0-10V air inlet).
Note that this parameter does not apply to 0-10V chimney dampers.
2. Press the down-arrow key, in order to select
Max.
Opening Mode
display.
3. Press
Adjust
then use the arrow keys to select the proper
opening mode (dumping / progressive).
4. Press
Adjust
once again to validate.
Adjusting the Temperature Compensation and Probe
Assignment
The temperature compensation is expressed as a percentage per
degree difference between the ambient temperature and the
average reading of the inlet’s probes. For each degree above or
below the average temperature, the inlet will open or close using
the compensation value. Set this value separately for each inlet. It
ranges from OFF to 10%. To deactivate compensation, press the
down arrow until compensation value displays “Off”.
To set the temperature compensation, proceed as follows:
1. Select the desired air inlet
: Air Inlet
1,
Air Inlet
2
Or
0-10v
Output
(0-10V air inlet). The actuator's position is
displayed on screen.
Note that this parameter does not apply to 0-10V chimney dampers.
Accessible if the chosen air inlet is enabled in the User Setup menu.
2. Press the down-arrow key to display the
T°
Compensation
parameter.
3. Press
Adjust
and then set the opening compensation to
the desired value.
4. Press
Adjust
again to validate.
5. Press the down-arrow key to display the probes. The
temperature probes that are assigned to the selected inlet
are displayed.
Содержание Smart Climate 310
Страница 1: ...Smart Climate 310 User s Guide 895 00676 REV 04 890 00582 REV 03...
Страница 12: ...12 Smart Climate 310 rev 03 Internal Switches Internal switches are located inside the auxiliary module...
Страница 96: ...96 Smart Climate 310 rev 03 Probe Assignment...
Страница 97: ...Smart Climate 310 rev 03 97 User Setup Menu...
Страница 98: ...98 Smart Climate 310 rev 03...
Страница 101: ...Smart Climate 310 rev 03 101 3 Press on the card and make it clip to the main board...
Страница 102: ...102 Smart Climate 310 rev 03...