![GSi Smart Climate 310 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/gsi/smart-climate-310/smart-climate-310_user-manual_2274990070.webp)
70 Smart Climate 310 rev. 03
Opening the Air Inlets Manually
It is possible to open (or close) each air inlet manually with the
relay switches of the auxiliary module. When an inlet is controlled
manually, the controller stops controlling it, lits up the "MANUAL
MODE" LED and stops monitoring potentiometer alarms.
To manually control an air inlet, proceed as follows:
1. Set the respective actuator's relay switch to the
Manual
position.
2. Use the other switch to open or close the actuator.
IMPORTANT:
Do not forget to return to the automatic mode
when you are done with the manual mode. To return to
automatic mode, select the
Auto
position with the upper switch.