Gremo1050F4 Instruction manual
5 User manual for GreControl control
5.11
Cab suspension
The cab suspension window can be accessed by pressing
in the main window and then
Cab suspension
once in
the settings window.
Fig. 65 GreControl, cab suspension settings
The cab suspension window displays from left to right:
Parameters:
•
Pressure Cab suspension (85)
sets value to make
cylinders work between min. and max., a greater value
= higher pressure
•
Pressure reduction Rear (0.85)
should differ approx.:
4-5 bar from the rear and front cylinders
•
Pressure Cab Height increase (1.50)
when machine
starts, the cab is raised using a pressure that is 1.5
times higher
•
100% = Y (40)
At an inclination of 40% the relevant side
gives 100% pressure to the cylinders to compensate for
the additional weight there, a vector of 0=0%, 40=100%
•
100% = Y (30)
at this side tilt the system produces
100% in the cylinders in question
•
Filter Y (93)
Filter value for tilt sensor Y
•
Filter X (93)
Filter value for tilt sensor X
•
Speed compensation (8)
percentage pressure
increase at variable speed
•
Speed for Comp. (3)
compensation speed
•
Extra
percentage pressure increase
at standstill (10)
•
Extra front standstill (5)
increases front pressure for 3
seconds to compensate for extra loads
Reconnection:
•
IND. Cab,
indicates when the cab is locked at the rear,
cab suspension is inactive if the cab is not locked
93
Содержание 1050F4
Страница 2: ......
Страница 70: ...66...
Страница 156: ...152...
Страница 164: ...160...
Страница 170: ...166...
Страница 184: ...180...
Страница 195: ...Gremo1050F4 Instruction manual 13 Technical data 13 15 Gremo s warranty 13 15 Gremo s warranty Fig 160 191...
Страница 197: ...193...
Страница 198: ...2019 last page...