Gremo1050F4 Instruction manual
2.17
Batteries
A Gremo can be equipped with wet cell or dry cell batteries.
When a dry cell battery is depleted, a diode will illuminate
red on the screen, or not illuminate at all. Wet cell batteries
must be checked so that the fluid level is above the cells.
Depleted batteries must be disposed of as hazardous
waste.
When start-up help is required, use corresponding series-
connected 24 V batteries and connect them over both
batteries’ poles: one battery’s + pole and the other
battery’s - pole or earth.
Do not use a start booster. The maximum permitted
voltage in the system is 28 V.
Charge the batteries using a battery charger designed for
a 24 V system.
2.18
Welding Repairs
NOTICE
Prior to beginning any welding, read this chapter
carefully!
• Turn off the main power switch.
• Disconnect the earth cable between the battery and the
frame.
• Disconnect the generator’s plus cables.
• Disconnect the fire extinguishing system’s central unit
by removing main fuse F57.
• Fit the safety screw in the fire extinguisher tank.
• Connect the ground terminal of the welding equipment
as close as possible to the welding location.
• Disconnect all computer cables when welding is taking
place near the cab. Engine control, air conditioning
system, DASA, GreControl, radio etc.
After any welding, ensure that you reset all the necessary
items correctly before restarting the machine.
CAUTION
Heated paint emits poisonous fumes which are
dangerous to inhale. Always remove all paint from the
welding location!
32